## Vibration Sensor: Pepperl+Fuchs VIM82PU-S1V16-2AE-I422K28 - Technical Specifications & Details
This document details the Pepperl+Fuchs VIM82PU-S1V16-2AE-I422K28 vibration sensor, outlining its features, technical specifications, installation, and programming details.
Key Features & Highlights:
️· Purpose: Measures vibration in the 0-16 mm/s range with ±0.1 mm/s accuracy.
️· Functional Safety: Certified to SIL 2 / PL d / Category 2, making it suitable for safety-critical applications.
️· Outputs: Provides relay outputs (2x NO), and a 4-20mA analog output for vibration variable.
️· Robust Design: Stainless steel housing (IP66/IP67) for industrial environments.
️· Programmability: Adjustable switching thresholds for the relay outputs.
Technical Specifications (Key Parameters):
️· Measurement Range: 0 - 16 mm/s (RMS)
️· Frequency Range: 10 - 1000 Hz
️· Operating Voltage: 24 V DC (±10%)
️· Current Consumption: Max. 100 mA
️· Ambient Temperature: -35 to +60 °C (-31 to +140 °F)
️· Housing Material: Stainless Steel 1.4305 / AISI 303
️· Degree of Protection: IP66/IP67
️· Certifications: SIL 2, PL d, Category 2. UL Listed
Installation & Programming:
️· Connection: 8-core cable with specific wiring for power, analog output, and relay contacts.
️· Mounting: The sensor should be securely mounted to minimize external influences.
️· Programming: Switching thresholds for the relay outputs are adjustable via rotary switches and a push button.
️· Documentation: Detailed installation, grounding, and mounting instructions are available in the sensor manual (accessible on the Pepperl+Fuchs website).
Accessories:
️· Flexible metal conduit (MEC-VIM6-V4A-1.5)
️· Mounting adapters (MONAD-M08-1,25-M08-1,25K/368 and MONAD-M08-1,25-M30-3,5/368)
Safety Information:
️· An external fuse (3A, semi-time-lag, 30V DC) is required.
️· Correct electrical connections and grounding are crucial for safe operation.
## Vibration Sensor: Pepperl+Fuchs VIM82PU-S1V16-2AE-I422K28 - Technical Specifications & Details
This document details the Pepperl+Fuchs VIM82PU-S1V16-2AE-I422K28 vibration sensor, outlining its features, technical specifications, installation, and programming details.
Key Features & Highlights:
️· Purpose: Measures vibration in the 0-16 mm/s range with ±0.1 mm/s accuracy.
️· Functional Safety: Certified to SIL 2 / PL d / Category 2, making it suitable for safety-critical applications.
️· Outputs: Provides relay outputs (2x NO), and a 4-20mA analog output for vibration variable.
️· Robust Design: Stainless steel housing (IP66/IP67) for industrial environments.
️· Programmability: Adjustable switching thresholds for the relay outputs.
Technical Specifications (Key Parameters):
️· Measurement Range: 0 - 16 mm/s (RMS)
️· Frequency Range: 10 - 1000 Hz
️· Operating Voltage: 24 V DC (±10%)
️· Current Consumption: Max. 100 mA
️· Ambient Temperature: -35 to +60 °C (-31 to +140 °F)
️· Housing Material: Stainless Steel 1.4305 / AISI 303
️· Degree of Protection: IP66/IP67
️· Certifications: SIL 2, PL d, Category 2. UL Listed
Installation & Programming:
️· Connection: 8-core cable with specific wiring for power, analog output, and relay contacts.
️· Mounting: The sensor should be securely mounted to minimize external influences.
️· Programming: Switching thresholds for the relay outputs are adjustable via rotary switches and a push button.
️· Documentation: Detailed installation, grounding, and mounting instructions are available in the sensor manual (accessible on the Pepperl+Fuchs website).
Accessories:
️· Flexible metal conduit (MEC-VIM6-V4A-1.5)
️· Mounting adapters (MONAD-M08-1,25-M08-1,25K/368 and MONAD-M08-1,25-M30-3,5/368)
Safety Information:
️· An external fuse (3A, semi-time-lag, 30V DC) is required.
️· Correct electrical connections and grounding are crucial for safe operation.
| Part No. | VIM82PU-S1V16-2AE-I422K28 |
| Manufacturer | PF |
| Size | 937 Kbytes |
| Pages | 4 pages |
| Description | Vibration sensor |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|