    1. Product Overview

    ️· Product Name: VOF-45 AC-DC Power Supply
    ️· Manufacturer: CUI Inc.
    ️· Date: September 30, 2011 (Release Date)
    ️· Warranty: 2-year limited warranty

    2. Available Models & Specifications

    ️· Output Voltage Options: 3.3V, 5V, 7.5V, 9V, 12V, 15V, 24V, 48V
    ️· Maximum Power: 45 Watts
    ️· Ripple and Noise: Measured at 20 MHz BW, using specific capacitor setup (0.1μF ceramic and 10μF electrolytic)
    ️· Key Specifications (typical):
    - Input Voltage: 85-264 VAC or 120-375 VDC
    - Input Frequency: 47-63 Hz
    - Input Current (110 VAC): 1 A
    - Input Current (220 VAC): 0.5 A
    - Inrush Current (110 VAC): 25 A
    - Inrush Current (220 VAC): 50 A
    - Line Regulation: ±0.5%
    - Load Regulation: ±1%
    - Switching Frequency: 60 kHz
    - Overvoltage Protection: 115%
    - Overcurrent Protection: Recovers at 105% Io
    - Isolation Voltage (Primary to Secondary): 3000 VAC
    - Isolation Voltage (Primary to Core): 1500 VAC
    - Leakage Current: 1.5 mA
    - Operating Temperature: 0°C to 60°C
    - Storage Temperature: -20°C to 85°C

    3. Compliance & Certifications

    ️· Safety Approvals: TUV EN60950, CE, UL/cUL 60950-1
    ️· EMI/EMC: FCC Class B, EN55022 Class B
    ️· RoHS Compliant: Yes
    ️· MTBF (Mean Time Between Failures): 250,000 hours (according to MIL-HDBK-217F)

    4. Physical Characteristics

    ️· Dimensions: 4 x 2 x 1.44 inches (102 x 51 x 36.6 mm)
    ️· Weight: 0.17 kg
    ️· Cooling Method: Free-air convection or forced air
    ️· Connector Type: Molex 2878 series crimp contacts

    5. Revision History

    ️· Revision 1.0 (04/03/2009): Initial Release
    ️· Revision 1.01 (05/02/2011): Updated dimensions in drawing
    ️· Revision 1.02 (05/13/2011): Applied new specification template
    ️· Revision 1.03 (09/30/2011): Added MTBF data.

    6. Important Notes

    ️· The document states that the product is *not* intended for use as a critical component in life-support equipment.
    ️· The document emphasizes that CUI Inc. is not responsible for infringements of patents or other rights.

    1. Product Overview

    ️· Product Name: VOF-45 AC-DC Power Supply
    ️· Manufacturer: CUI Inc.
    ️· Date: September 30, 2011 (Release Date)
    ️· Warranty: 2-year limited warranty

    2. Available Models & Specifications

    ️· Output Voltage Options: 3.3V, 5V, 7.5V, 9V, 12V, 15V, 24V, 48V
    ️· Maximum Power: 45 Watts
    ️· Ripple and Noise: Measured at 20 MHz BW, using specific capacitor setup (0.1μF ceramic and 10μF electrolytic)
    ️· Key Specifications (typical):
    - Input Voltage: 85-264 VAC or 120-375 VDC
    - Input Frequency: 47-63 Hz
    - Input Current (110 VAC): 1 A
    - Input Current (220 VAC): 0.5 A
    - Inrush Current (110 VAC): 25 A
    - Inrush Current (220 VAC): 50 A
    - Line Regulation: ±0.5%
    - Load Regulation: ±1%
    - Switching Frequency: 60 kHz
    - Overvoltage Protection: 115%
    - Overcurrent Protection: Recovers at 105% Io
    - Isolation Voltage (Primary to Secondary): 3000 VAC
    - Isolation Voltage (Primary to Core): 1500 VAC
    - Leakage Current: 1.5 mA
    - Operating Temperature: 0°C to 60°C
    - Storage Temperature: -20°C to 85°C

    3. Compliance & Certifications

    ️· Safety Approvals: TUV EN60950, CE, UL/cUL 60950-1
    ️· EMI/EMC: FCC Class B, EN55022 Class B
    ️· RoHS Compliant: Yes
    ️· MTBF (Mean Time Between Failures): 250,000 hours (according to MIL-HDBK-217F)

    4. Physical Characteristics

    ️· Dimensions: 4 x 2 x 1.44 inches (102 x 51 x 36.6 mm)
    ️· Weight: 0.17 kg
    ️· Cooling Method: Free-air convection or forced air
    ️· Connector Type: Molex 2878 series crimp contacts

    5. Revision History

    ️· Revision 1.0 (04/03/2009): Initial Release
    ️· Revision 1.01 (05/02/2011): Updated dimensions in drawing
    ️· Revision 1.02 (05/13/2011): Applied new specification template
    ️· Revision 1.03 (09/30/2011): Added MTBF data.

    6. Important Notes

    ️· The document states that the product is *not* intended for use as a critical component in life-support equipment.
    ️· The document emphasizes that CUI Inc. is not responsible for infringements of patents or other rights.

    Part No.VOF-45_11
    ManufacturerCUI
    Size237 Kbytes
    Pages5 pages
    DescriptionAC-DC POWER SUPPLY
    Does ALLDATASHEET help your business so far?  [ DONATE ] 

    About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com