119 / 205 page ![]() SMSC DS – LPC47M14X Page 119 Rev. 03/19/2001 FANx Registers The FAN1 and FAN2 Registers are located at 0x56 and 0x57 from base I/O in Logical Device A. The bits are defined below. See the register description in the “Runtime Registers” section. Fan x Clock Select Bit, D7 The Fan x Clock select bit in the FANx registers is used with the Fan x Clock Source Select and the Fan x Clock Multiplier bits in the Fan Control register to determine the fan speed FOUT. See Table 57 above. Duty Cycle Control for Fan x, Bits D6 – D1 The Duty Cycle Control (DCC) bits determine the fan duty cycle. The LPC47M14x has ≈1.56% duty cycle resolution. When DCC = “000000” (min. value), FOUT is always low. When DCC is “111111” (max. value), FOUT is almost always high; i.e., high for 63/64 th and low for 1/64th of the FOUT period. Generally, the FOUT duty cycle (%) is (DCC ÷ 64) × 100. Fan x Clock Control, Bit D0 The Fan x Clock Control bit D0 is used to override the Duty Cycle Control for Fan x bits and force FOUT always high. When D0 = “0”, the DCC bits determine the FOUT duty cycle. When D0 = 1, FOUT is always high, regardless of the state of the DCC bits. Fan Control Register The Fan Control Register is located at 0x58 from base I/O in Logical Device A. The bits are defined below. See the register description in the “Runtime Registers” section. Fan x Count Divisor, Bits D7-D6 / D5-D4 Fan x Count Divisor bit in Fan Control Register is used to determine fan tachometer count. The choices for the divisor are 1, 2, 4 and 8. See “Fan Tachometer Input” section. Fan x Clock Multiplier, Bits D3 / D2 The Fan x Clock Multiplier bit is used with the Fan x Clock Source Select bit in the Fan Control Register and the Fan x Clock Select bit in Fan register to determine the FOUT. When the Fan x Clock Multiplier bit = “0”, no clock multiplier is used. When the Fan x Clock Multiplier bit = “1”, the clock speed determined by the Fan x Clock Source Select bit is doubled. Fan x Clock Source Select, Bits D1 / D0 The Fan x Clock Source Select and the Fan x Clock Multiplier bits in the Fan Control register is used with the Fan x Clock Select bit in the Fan x registers to determine the fan speed FOUT. See Table 57 above. 6.17.2 Fan Tachometer Inputs The LPC47M14x implements fan tachometer inputs for signals from fans equipped with tachometer outputs. The part can generate both a PME and an SMI when the fan speed drops below a predetermined value. See description below. The clock source for the tachometer count is the 32.768kHz oscillator. The Fan Tachometer Inputs gate a divided down version of the 32.768kHz oscillator for one period of the Fan signal into an 8-bit counter (maximum count is 255). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |