224 / 286 page ![]() System voltage diagnostics L9680 224/286 DS11615 Rev 7 For measurements other than voltage (current, resistance, temperature etc.) the ranges are specified in the electrical parameters section of the relevant block. 14.1 Analog to digital algorithmic converter The device hosts an integrated 10-bit Analog to Digital converter, running at a clock frequency of 16 MHz. The ADC output is processed by a D to D converter with the following functions: Use of trimming bits to recover additional gain error due to resistor dividers mismatch; Digital low-pass filtering; Conversion from 12 to 10 bits. 10 bits data are filtered inside the digital section. The number of samples that are filtered vary depending on the chosen conversion. As per Section 7.4.2, the number of used samples in converting DC sensor, squib/pyroswitch or temperature measurements defaults to 8. The number of samples for all other measurements defaults to 4. The sample number can be configured by accessing the SYS_CFG register. After low pass filter, the residual total error is ±4 LSB. This error figure applies to the case of a ideal reference voltage: the spread of reference voltage causes a proportional error in the conversion output. The reference voltage of the ADC is set to 2.5 V. The conversion time is comprised of several factors: the number of measurements loaded into the queue, the number of samples taken for any one measurement, and the various settling times. An example of conversion time calculation for a full ADC request queue is reported in Figure 70. The timings reported in Figure 70 are nominal ones, min/max values can be obtained by considering the internal oscillator frequency variation reported in the DC characteristics section. VBATMON X WAKEUP X SATBUCK X WDT/TM X RSUx X VCC X CVDD X VINT X VCOREMON X Bandgap (BGR/BGM) X Table 19. Diagnostics divider ratios (continued) Measurements Divider Ratio 15:1 10:1 7:1 4:1 1:1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |