438 / 508 page ![]() Section 16 Electrical Characteristics Rev. 1.00 May 30, 2008 Page 418 of 484 REJ09B0436-0100 Values Item Symbol Min Typ Max Unit Test Conditions Wait time after SWE-bit setting* 1 x 1 — — µs Wait time after ESU-bit setting* 1 y 100 — — µs Wait time after E-bit setting* 1 *6 z 10 — 100 ms Wait time after E-bit clear* 1 α 10 — — µs Wait time after ESU-bit clear* 1 β 10 — — µs Wait time after EV-bit setting* 1 γ 20 — — µs Wait time after dummy write* 1 ε 2 — — µs Wait time after EV-bit clear* 1 η 4 — — µs Wait time after SWE-bit clear* 1 θ 100 — — µs Erase Maximum erase count* 1 *6*7 N — — 120 times Notes: 1. Set the times according to the program/erase algorithms. 2. Programming time per 128 bytes (Shows the total period for which the P bit in FLMCR1 is set. It does not include the programming verification time.) 3. Block erase time (Shows the total period for which the E bit in FLMCR1 is set. It does not include the erase verification time.) 4. Maximum programming time (t P (max)) t P (max) = Wait time after P-bit setting (z) × maximum number of writes (N) 5. The maximum number of writes (N) should be set according to the actual set value of z1, z2, and z3 to allow programming within the maximum programming time (t P (max)). The wait time after P-bit setting (z1 and z2) should be alternated according to the number of writes (n) as follows: 1 ≤ n ≤ 6 z1 = 30 µs 7 ≤ n ≤ 1000 z2 = 200 µs 6. Maximum erase time (t E (max)) t E (max) = Wait time after E-bit setting (z) × maximum erase count (N) 7. The maximum number of erases (N) should be set according to the actual set value of z to allow erasing within the maximum erase time (t E (max)). 8. This minimum value guarantees all characteristics after reprogramming (the guaranteed range is from 1 to the minimum value). 9. Reference value when the temperature is 25 °C (normally reprogramming will be performed by this count). 10. This is a data retain characteristic when reprogramming is performed within the specification range including this minimum value. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |