210 / 366 page ![]() PIC18CXX8 DS30475A-page 210 Advanced Information 2000 Microchip Technology Inc. 17.3 CAN Modes of Operation The PIC18CXX8 has the following modes of operation. These modes are: • Configuration mode • Disable mode • Normal Operation mode • Listen Only mode • Loopback mode • Error Recognition mode (selected through CANRXM bits) Modes are requested by setting the REQOP bits, except the Error Recognition mode, which is requested through the CANRXM bits. Entry into a mode is acknowledged by monitoring the OPMODE bits. When changing modes, the mode will not actually change until all pending message transmissions are complete. Because of this, the user must verify that the device has actually changed into the requested mode before further operations are executed. 17.3.1 CONFIGURATION MODE The CAN module has to be initialized before the activa- tion. This is only possible if the module is in the Config- uration mode. The Configuration mode is requested by setting REQOP2 bit. Only when the status bit OPMODE2 has a high level, the initialization can be performed. Afterwards, the configuration registers and the acceptance mask registers and the acceptance fil- ter registers can be written. The module is activated by setting the control bits CFGREQ to zero. The module will protect the user from accidentally vio- lating the CAN protocol through programming errors. All registers which control the configuration of the mod- ule can not be modified while the module is on-line. The CAN module will not be allowed to enter the Con- figuration mode while a transmission is taking place. The CONFIG bit serves as a lock to protect the follow- ing registers. • Configuration registers • Bus Timing registers • Identifier Acceptance Filter registers • Identifier Acceptance Mask registers In the Configuration mode, the module will not transmit or receive. The error counters are cleared and the inter- rupt flags remain unchanged. The programmer will have access to configuration registers that are access restricted in other modes. 17.3.2 DISABLE MODE In Disable mode, the module will not transmit or receive. The module has the ability to set the WAKIF bit due to bus activity, however, any pending interrupts will remain and the error counters will retain their value. If REQOP<2:0> is set to 001, the module will enter the module Disable mode. This mode is similar to dis- abling other peripheral modules by turning off the mod- ule enables. This causes the module internal clock to stop unless the module is active (i.e., receiving or transmitting a message). If the module is active, the module will wait for 11 recessive bits on the CAN bus, detect that condition as an idle bus, then accept the module disable command. OPMODE<2:0>=001 indi- cates whether the module successfully went into mod- ule Disable mode The WAKIF interrupt is the only module interrupt that is still active in the module Disable mode. If the WAKIE is set, the processor will receive an interrupt whenever the CAN bus detects a dominant state, as occurs with a SOF. The I/O pins will revert to normal I/O function when the module is in the module Disable mode. 17.3.3 NORMAL MODE This is the standard operating mode of the PIC18CXX8. In this mode, the device actively monitors all bus messages and generates acknowledge bits, error frames, etc. This is also the only mode in which the PIC18CXX8 will transmit messages over the CAN bus. 17.3.4 LISTEN ONLY MODE Listen Only mode provides a means for the PIC18CXX8 to receive all messages, including mes- sages with errors. This mode can be used for bus mon- itor applications, or for detecting the baud rate in ‘hot plugging’ situations. For auto-baud detection, it is nec- essary that there are at least two other nodes which are communicating with each other. The baud rate can be detected empirically by testing different values until valid messages are received. The Listen Only mode is a silent mode, meaning no messages will be transmit- ted while in this state, including error flags or acknowl- edge signals. The filters and masks can be used to allow only particular messages to be loaded into the receive registers, or the filter masks can be set to all zeros to allow a message with any identifier to pass. The error counters are reset and deactivated in this state. The Listen Only mode is activated by setting the mode request bits in the CANCON register. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |