AI

The **E5GN-R2HT-C** is a high-performance digital temperature controller manufactured by **Omron**. It belongs to the E5GN series, which is characterized by its compact 1/32 DIN size (48 x 24 mm).
---
## 1. Technical Specifications Breakdown
The alphanumeric code "R2HT-C" provides specific details about its internal electronic components and capabilities:
| Code Segment | Feature | Description |
| :--- | :--- | :--- |
| **E5GN** | Series | Compact 1/32 DIN Temperature Controller |
| **R** | Control Output | **Relay Output**: SPST-NO, 250 VAC, 2 A |
| **2** | Auxiliary Outputs | **Two Auxiliary Outputs**: Typically used for alarms |
| **H** | Heater Burnout | Includes **Heater Burnout (HB) detection** (requires CT) |
| **T** | Transfer Output | Supported (varies by sub-model configuration) |
| **C** | Case Color | Black case |
---
## 2. Key Electronic Components
### Control Output (Relay)
Unlike SSR (Solid State Relay) models, the "R" designation means this unit contains a mechanical relay.
* **Switching Capacity:** 250 VAC at 2 Amps.
* **Best Use:** Best for driving contactors or slow-switching heating elements. Not recommended for high-frequency PID switching (which would cause premature wear).
### Input Sensors (Universal)
The electronics are designed to process a wide range of analog signals:
* **Thermocouples:** K, J, T, E, L, U, N, R, S, B, W.
* **Platinum Resistance Thermometers:** Pt100 or JPt100.
* **Non-contact Temperature Sensors:** ES1B.
* **Analog Input:** 4 to 20 mA or 1 to 5 VDC (depending on internal jumper/setting).
### Power Supply
* **Standard Range:** 100 to 240 VAC, 50/60 Hz.
* **Internal Circuitry:** Features a switching power supply designed to withstand voltage fluctuations in industrial environments.
---
## 3. Advanced Electronic Features
### 2-PID Control
The unit uses a sophisticated PID algorithm that prevents overshoot while maintaining high-speed response to disturbances. It electronically calculates the optimal proportional, integral, and derivative constants.
### Heater Burnout (HB) Detection
The "H" in the model name indicates the presence of a **Current Transformer (CT)** input. The controller monitors the current flowing to the heater:
* If the current drops below a set threshold while the control output is ON, the controller triggers an alarm.
* This is critical for identifying failing heating elements before they cause process failures.
### 11-Segment Display
The front panel uses a high-contrast, 11-segment LCD display that allows for clearer alphanumeric characters compared to standard 7-segment displays, making parameter settings easier to navigate.
---
## 4. Wiring Diagram Overview
| Terminal Number | Function |
| :--- | :--- |
| **1 & 2** | Control Output (Relay) |
| **3 & 4** | Auxiliary Output 1 (Alarm) |
| **5 & 6** | Auxiliary Output 2 (Alarm) |
| **7 & 8** | Power Supply (100-240 VAC) |
| **9, 10, 11** | Sensor Inputs (Thermocouple/Pt100) |
| **12** | CT (Current Transformer) Input |
- ⤷
What is the difference between the E5GN-R2HT and the E5GN-Q2HT models?
- ⤷ How do I wire a Current Transformer (CT) to this controller for heater burnout detection?
- ⤷ Can this controller be used with a 4-20mA signal instead of a thermocouple?