M2MST-Z-R2/N
AI

Based on the product code provided, the **M2MST-Z-R2/N** belongs to the **M2 Series** of signal conditioners manufactured by **M-System** (now part of **MG CO., LTD.**).
Specifically, this model is a **Potentiometer Transmitter**. It is designed to track the position of a potentiometer (slidewire) and convert that resistance change into a standard instrumentation signal (like 4-20mA or 0-10V).
---
## Technical Specifications Breakdown
The alphanumeric suffix in the model number defines the specific electronic configuration:
| Segment | Code | Description |
| :--- | :--- | :--- |
| **Model** | M2MST | Potentiometer Transmitter (Plug-in type) |
| **Input** | Z | Potentiometer (Total resistance 100 $\Omega$ to 10 k$\Omega$) |
| **Output** | R2 | 4 – 20 mA DC (Load resistance 550 $\Omega$ max) |
| **Power Input** | /N | 100 – 240V AC (Operating voltage range 85 – 264V) |
---
## Key Features
### 1. Galvanic Isolation
This device provides three-way isolation between:
* **Input** (The potentiometer/sensor)
* **Output** (The PLC/Controller/DCS)
* **Power** (The AC supply)
This protects sensitive control electronics from ground loops and electrical surges.
### 2. High Resolution and Accuracy
* **Accuracy:** Typically within ±0.1% of span.
* **Temp. Coefficient:** ±0.015% per °C.
### 3. Physical Design
* **Construction:** Plug-in base structure.
* **Wiring:** Terminals are located on the base, allowing the electronic module to be replaced without disconnecting wires.
* **LED Indicator:** Power indicator on the front panel.
---
## Wiring and Connections
The device typically follows a standard terminal pin-out for the M2 series base:
| Terminal No. | Function | Connection Type |
| :--- | :--- | :--- |
| **1** | Output (+) | 4-20mA Signal |
| **2** | Output (-) | Common |
| **3** | Input (1) | Potentiometer High |
| **4** | Input (2) | Potentiometer Wiper |
| **5** | Input (3) | Potentiometer Low |
| **7** | Power (L) | 100-240V AC |
| **8** | Power (N) | 100-240V AC |
---
## Application Use Case
This part is commonly used in industrial automation for:
* **Valve Position Feedback:** Converting the mechanical rotation of a valve into a 4-20mA signal for a PLC.
* **Level Sensing:** Using a float-operated potentiometer to measure tank levels.
* **Actuator Tracking:** Monitoring the stroke position of linear actuators.
- ⤷