MDL-2-1SLASH4-R
AI

The **MDL-2-1/4-R** is a specific model of electronic fuse manufactured by Eaton (Bussmann Series). It is a time-delay (slow-blow) glass tube fuse widely used in power supplies and industrial equipment.
### 1. Technical Specifications
Below are the primary electrical and physical characteristics of this component:
| Feature | Specification |
| :--- | :--- |
| **Current Rating** | 2.25 Amps (2-1/4 A) |
| **Voltage Rating (AC)** | 250 VAC |
| **Fuse Type** | Time-Delay / Slow-Blow |
| **Material** | Glass Tube with Nickel-plated brass endcaps |
| **Physical Size** | 1/4" x 1-1/4" (6.3mm x 32mm) |
| **Interrupt Rating** | 100A at 250VAC / 10,000A at 125VAC |
| **RoHS Compliant** | Yes (Indicated by the "-R" suffix) |
---
### 2. Breakdown of the Part Number
Understanding the nomenclature helps in identifying equivalent parts or replacements:
* **MDL**: The series name, signifying a time-delay glass tube fuse (standard 1/4" x 1-1/4").
* **2-1/4**: The amperage rating. In decimal form, this is **2.25 Amps**.
* **-R**: Indicates the part is **RoHS compliant** (lead-free).
---
### 3. Key Electronic Characteristics
#### A. Time-Delay (Slow-Blow) Mechanism
Unlike "Fast-Acting" fuses, the MDL series is designed to withstand temporary surges in current. This is crucial for inductive loads like **motors or transformers** that experience a high "inrush current" when first powered on. The fuse will not blow immediately if the current slightly exceeds 2.25A for a fraction of a second, but it will blow if a sustained overload or short circuit occurs.
#### B. Interrupting Rating
This defines the maximum fault current the fuse can safely stop without physically exploding or arcing. The MDL-2-1/4-R is rated to handle up to **10,000 Amps** at a lower voltage (125V), making it very safe for standard household and light industrial circuits.
#### C. Typical Applications
* **Power Supplies:** Protecting the primary side of transformers.
* **Consumer Electronics:** Used in older audio amplifiers and appliances.
* **Industrial Control:** Protecting solenoid valves or small motors.
---
### 4. Safety and Replacement Note
When replacing this part, ensure the replacement is also a **Time-Delay** fuse. Replacing a slow-blow MDL fuse with a fast-acting fuse (like the AGC series) will likely result in the fuse blowing immediately upon startup, even if the device is functioning correctly.
- ⤷
What is the difference between an MDL and an AGC series fuse?
- ⤷ Can I use a 2.5A fuse if a 2.25A fuse is not available?
- ⤷ How do I test if an MDL-2-1/4-R fuse is blown using a multimeter?