The **PKE-SWD-32** is a specialized communication module manufactured by Eaton. It is designed to bridge a **PKE motor-protective circuit breaker** with a **SmartWire-DT (SWD)** network.
This device transforms a traditional analog/mechanical protection component into a "smart" industrial automation node.
### Core Electronic Components & Architecture
| Component Group | Function |
| :--- | :--- |
| **Microcontroller (MCU)** | The "brain" that processes sensor data from the PKE trip block and manages communication protocols. |
| **SmartWire-DT ASIC** | An application-specific integrated circuit that handles high-speed data transmission and addressing on the SWD bus. |
| **Optocouplers/Isolation** | Provides electrical isolation between the high-power PKE circuit breaker and the low-voltage communication bus. |
| **Interface Pins** | Direct physical connection points that plug into the PKE-XTU trip block to read thermal and magnetic status. |
| **Status LEDs** | Small SMD LEDs (usually green/red) that indicate the health of the SWD network and the status of the breaker. |
---
### Data Transmission Capabilities
The electronic circuitry inside the PKE-SWD-32 allows for the digital transmission of the following parameters over the network:
1. **Status Monitoring:**
* Switching state (ON, OFF, Tripped).
* Reason for trip (Overload, Short-circuit).
2. **Current Measurement:**
* Real-time reporting of the motor current (relative value in %).
* Thermal load of the motor.
3. **Control Signals:**
* Remote resetting of the trip block (depending on the PKE model).
---
### Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Power Supply** | Supplied via SmartWire-DT ribbon cable (15 VDC / 24 VDC). |
| **Connection Method** | Plug-in technology (direct mounting on PKE). |
| **Address Setting** | Automatic via the SWD configuration button. |
| **Communication Protocol** | SmartWire-DT (based on CAN architecture principles). |
| **Current Consumption** | Typically ~37 mA. |
---
### Integration Logic
In a typical control cabinet setup, the electronics of the PKE-SWD-32 act as a **Slave** device. It continuously polls the PKE trip block's internal sensors and converts the analog physical values into digital packets. These packets are then sent through the green SWD ribbon cable to the **SWD Gateway** (Master), which communicates with a PLC (like an EasyControl or XC-series).
- ⤷