Electronic Components Datasheet Search
  New Zealand  ▼
ALLDATASHEET.CO.NZ

X  

  • PKE-SWD-32..

  • AI
    ## Electronic Components and Functionality of the PKE-SWD-32 The **PKE-SWD-32** is a specialized communication module manufactured by Eaton. It is designed to bridge a **PKE motor-protective circuit breaker** with a **SmartWire-DT (SWD)** network. This device transforms a traditional analog/mechanical protection component into a "smart" industrial automation node. ### Core Electronic Components & Architecture | Component Group | Function | | :--- | :--- | | **Microcontroller (MCU)** | The "brain" that processes sensor data from the PKE trip block and manages communication protocols. | | **SmartWire-DT ASIC** | An application-specific integrated circuit that handles high-speed data transmission and addressing on the SWD bus. | | **Optocouplers/Isolation** | Provides electrical isolation between the high-power PKE circuit breaker and the low-voltage communication bus. | | **Interface Pins** | Direct physical connection points that plug into the PKE-XTU trip block to read thermal and magnetic status. | | **Status LEDs** | Small SMD LEDs (usually green/red) that indicate the health of the SWD network and the status of the breaker. | --- ### Data Transmission Capabilities The electronic circuitry inside the PKE-SWD-32 allows for the digital transmission of the following parameters over the network: 1. **Status Monitoring:** * Switching state (ON, OFF, Tripped). * Reason for trip (Overload, Short-circuit). 2. **Current Measurement:** * Real-time reporting of the motor current (relative value in %). * Thermal load of the motor. 3. **Control Signals:** * Remote resetting of the trip block (depending on the PKE model). --- ### Technical Specifications | Feature | Specification | | :--- | :--- | | **Power Supply** | Supplied via SmartWire-DT ribbon cable (15 VDC / 24 VDC). | | **Connection Method** | Plug-in technology (direct mounting on PKE). | | **Address Setting** | Automatic via the SWD configuration button. | | **Communication Protocol** | SmartWire-DT (based on CAN architecture principles). | | **Current Consumption** | Typically ~37 mA. | --- ### Integration Logic In a typical control cabinet setup, the electronics of the PKE-SWD-32 act as a **Slave** device. It continuously polls the PKE trip block's internal sensors and converts the analog physical values into digital packets. These packets are then sent through the green SWD ribbon cable to the **SWD Gateway** (Master), which communicates with a PLC (like an EasyControl or XC-series).
    ✨ Follow-up Questions
    • ⤷ How do I configure the SWD address for the PKE-SWD-32?
    • ⤷ What are the specific LED blink codes for troubleshooting this module?
    • ⤷ Can the PKE-SWD-32 be used with any standard circuit breaker or only Eaton PKE series?