Electronic Components Datasheet Search
  New Zealand  ▼
ALLDATASHEET.CO.NZ

X  

VMS-160-5 Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about VMS-160-5_11 Datasheet

  • # Example questions: ➢ What is the mtbf (mean time between failures) of the vms-160 with 400 lfm forced air, as stated in the document?
    ➢ What type of connector is specified for cn2?
    ➢ What is the maximum operating temperature specified for the vms-160 power supply, according to the derating curve?

  • Part No.VMS-160-5_11
    ManufacturerCUI
    Size330 Kbytes
    Pages5 pages
    DescriptionAC-DC POWER SUPPLY
    Datasheet Summary with AI

    1. Product Overview:

    ️· Product: VMS-160 Power Supply
    ️· Manufacturer: CUI Inc.
    ️· Type: AC-DC Power Supply

    2. Key Features & Specifications:

    ️· Input Voltage: Not explicitly stated, but assumed to be standard AC voltage.
    ️· Output Power: Up to 100W (see derating curves).
    ️· Operating Temperature: -20°C to 50°C (derating required outside this range).
    ️· Storage Temperature: -40°C to 80°C
    ️· Humidity: 8% - 90% non-condensing (operating)
    ️· Certifications/Compliance: RoHS compliant, MTBF (Mean Time Between Failures) of 200,000 hours (with forced air cooling).
    ️· Safety: Meets IEC 60950-1 leakage current requirements.
    ️· Protection: Includes various protections (not explicitly listed, but implied by the general nature of power supplies).
    ️· Forced Air Cooling: The power supply is designed to be used with forced air cooling. Derating is required above -20°C.

    3. Environmental and Mechanical Details:

    ️· Shock: 10G operating, 140G non-operating
    ️· Vibration: 1 Grms operating, 2 Grms non-operating
    ️· Mechanical Dimensions: Not explicitly detailed in numerical form, but shown in the mechanical drawing.
    ️· Connectors: Specific connectors are mentioned - MOLEX.

    4. Derating Curves:

    ️· Illustrate how maximum output power decreases as the ambient temperature increases. This is critical for operating the power supply within its specified limits.
    ️· Shows the difference between convection (natural cooling) and forced air cooling (using a fan).

    5. Revision History:

    ️· Revision 4.0 (June 6, 2011): Initial release of the specification.
    ️· Revision 1.01: Updated the specification template.

    6. Warranty and Disclaimer:

    ️· Two-year limited warranty.
    ️· Standard disclaimer regarding product changes and liability.
    ️· The product is not authorized for use as critical components in life-support systems.

    7. Contact Information:

    ️· Website: cui.com
    ️· Technical Support: techsupport@cui.com
    ️· Phone: 800.275.4899
    ️· Address: 20050 SW 112th Ave, Tualatin, OR 97062

    1. Product Overview:

    ️· Product: VMS-160 Power Supply
    ️· Manufacturer: CUI Inc.
    ️· Type: AC-DC Power Supply

    2. Key Features & Specifications:

    ️· Input Voltage: Not explicitly stated, but assumed to be standard AC voltage.
    ️· Output Power: Up to 100W (see derating curves).
    ️· Operating Temperature: -20°C to 50°C (derating required outside this range).
    ️· Storage Temperature: -40°C to 80°C
    ️· Humidity: 8% - 90% non-condensing (operating)
    ️· Certifications/Compliance: RoHS compliant, MTBF (Mean Time Between Failures) of 200,000 hours (with forced air cooling).
    ️· Safety: Meets IEC 60950-1 leakage current requirements.
    ️· Protection: Includes various protections (not explicitly listed, but implied by the general nature of power supplies).
    ️· Forced Air Cooling: The power supply is designed to be used with forced air cooling. Derating is required above -20°C.

    3. Environmental and Mechanical Details:

    ️· Shock: 10G operating, 140G non-operating
    ️· Vibration: 1 Grms operating, 2 Grms non-operating
    ️· Mechanical Dimensions: Not explicitly detailed in numerical form, but shown in the mechanical drawing.
    ️· Connectors: Specific connectors are mentioned - MOLEX.

    4. Derating Curves:

    ️· Illustrate how maximum output power decreases as the ambient temperature increases. This is critical for operating the power supply within its specified limits.
    ️· Shows the difference between convection (natural cooling) and forced air cooling (using a fan).

    5. Revision History:

    ️· Revision 4.0 (June 6, 2011): Initial release of the specification.
    ️· Revision 1.01: Updated the specification template.

    6. Warranty and Disclaimer:

    ️· Two-year limited warranty.
    ️· Standard disclaimer regarding product changes and liability.
    ️· The product is not authorized for use as critical components in life-support systems.

    7. Contact Information:

    ️· Website: cui.com
    ️· Technical Support: techsupport@cui.com
    ️· Phone: 800.275.4899
    ️· Address: 20050 SW 112th Ave, Tualatin, OR 97062

    Part No.VMS-160-5_11
    ManufacturerCUI
    Size330 Kbytes
    Pages5 pages
    DescriptionAC-DC POWER SUPPLY
    Does ALLDATASHEET help your business so far?  [ DONATE ] 

    About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com