| Electronic Components Datasheet Search |
|
RER120-26/18/2TDP Datasheet(PDF) 1 Page - ebm-papst |
|
|
|||||||||||||||||||||||||||||
RER120-26/18/2TDP Datasheet(HTML) 1 Page - ebm-papst |
|
|
1 / 1 page ![]() – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Moisture protection Max. 390 m3/h – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake, Centrifugal: Exhaust – Direction of rotation: Clockwise, looking towards rotor – Connection: via single wires AWG 18, 20 or AWG 22, TR 64. Speed signal and control input AWG 22 – Highlights: Highly efficient and smoothly operating 3-phase fan drive Backward-curved impeller – Weight: 430 g 1) Fiberglass-reinforced plastic Type m3/h cfm VDC VDC Bel(A) / Watts rpm-1 °C Hours Hours RER 120-26/14/2 TDMP* 320 188 24 16...32 tbd 51 5 200 -20...+60 60 000 / 37 500 102 500 ¿ RER 120-26/14/2 TDP 377 222 24 16...32 8.2 78 6 100 -20...+60 55 000 / 35 000 92 500 ¡ RER 120-26/18/2 TDMP* 320 188 48 36...60 tbd 51 5 200 -20...+60 57 500 / 35 000 97 500 ¿ RER 120-26/18/2 TDP 390 230 48 36...60 8.3 92 6 300 -20...+60 50 000 / 30 000 85 000 ¬ Subject to change * On request The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 140 x 140 mm. Cover plate 140 x 140 mm, with an air inlet opening Ø 94.4 mm, arranged concentrically to the impeller. Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, maximum speed if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the positive and negative wires. Please note the wiring suggestion. Tin-plated 112 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Inlet rings from p. 252 DC centrifugal fans Ø 120 x 54 mm Series RER 120 TD Nominal data |
Similar Part No. - RER120-26/18/2TDP |
|
Similar Description - RER120-26/18/2TDP |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |