| Electronic Components Datasheet Search |
|
HAL1002 Datasheet(PDF) 13 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
HAL1002 Datasheet(HTML) 13 Page - Micronas |
|
13 / 29 page ![]() DATA SHEET HAL 1002 Micronas April 25, 2014; DSH000163_001EN 13 By pressing the key “calibrate and store”, the software will calculate the corresponding parameters for Sensitivity, VOQ, Low-Level, High-Level and stores these values in the EEPROM. This calibration must be done individually for each sensor. The sensor is now calibrated for the customer application. However, the programming can be changed again and again if necessary. Fig. 3–1: Characteristics of a position switch Step 3: Locking the Sensor The last step is activating the LOCK function with the “lock” key. The sensor is now locked and does not respond to any programming or reading commands. Warning: The LOCK register cannot be reset! 3.5. Example: Calibration of a Position Switch The following description explains the calibration procedure using a position switch as an example: – The mechanical switching points are given. – temperature coefficient of the magnet: 500 ppm/K Step 1: Input of the registers which need not be adjusted individually The register values for the following registers are given for all sensors in the application: –FILTER Select the filter frequency: 500 Hz –RANGE Select the magnetic field range: 30 mT –TC For this magnetic material: 6 –TCSQ For this magnetic material: 14 Enter these values in the software and use the “write and store” command to store these values permanently in the registers. Step 2: Calculation of the Sensor Parameters Set the system to the calibration point where the sensor output must be high and press “Readout BOFF”. Set the system to the calibration point where the sensor output must be low and press “Readout BON”. Now, adjust the hysteresis to 80% and press the key “calibrate and store”. Step 3: Locking the Sensor The last step is activating the LOCK function with the “LOCK” command. The sensor is now locked and does not respond to any programming or reading commands. Please note that the LOCK function becomes effective after power-down and power-up of the Hall-IC. Warning: The LOCK register cannot be reset! Sensor switched on VOUT position Sensor switched off Calibration points Sensor switched on Hysteresis (here 80 %) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |