LTC3626 Datasheet(PDF) 20 Page - Linear Technology

Part # LTC3626
Description  20V, 2.5A Synchronous Monolithic Step-Down Regulator with Current and Temperature Monitoring
PDF  28 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  LINER [Linear Technology]
Direct Link  http://www.linear.com
Logo LINER - Linear Technology

LTC3626 Datasheet(HTML) 20 Page - Linear Technology

Back Button LTC3626 Datasheet HTML 16Page - Linear Technology LTC3626 Datasheet HTML 17Page - Linear Technology LTC3626 Datasheet HTML 18Page - Linear Technology LTC3626 Datasheet HTML 19Page - Linear Technology LTC3626 Datasheet HTML 20Page - Linear Technology LTC3626 Datasheet HTML 21Page - Linear Technology LTC3626 Datasheet HTML 22Page - Linear Technology LTC3626 Datasheet HTML 23Page - Linear Technology LTC3626 Datasheet HTML 24Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 28 page
background image
LTC3626
20
3626fa
For more information www.linear.com/LTC3626
applicaTions inForMaTion
above. During normal operation, if the output drops below
10% of its final value, as it may when tracking down for
instance, the regulator will automatically switch to Burst
Modeoperationtopreventinductorsaturationandimprove
TRACK/SS pin accuracy.
Output Power Good
The PGOOD output of the LTC3626 is driven by a 20Ω
(typical)open-drainpull-downdevice.Thispinwillbecome
high impedance once the output voltage is within 5%
(typical) of the target regulation point allowing the volt-
age at PGOOD to rise via an external pull-up resistor. If
the output voltage exits a 8% (typical) regulation window
around the target regulation point, the open-drain output
will pull down to ground, thereby dropping the PGOOD
pin voltage. A filter time of 40μs (typical) acts to prevent
unwanted PGOOD output changes during VOUT transient
events. As a result, the output voltage must be within
the target regulation window of 5% for 40μs before the
PGOOD pin is pulled high. Conversely, the output voltage
must exit the 8% regulation window for 40μs before the
PGOOD pin pulls to ground (see Figure 4).
PGOOD
VOLTAGE
VOUT
–8% –5%
5%
8%
3626 F04
0%
NOMINAL OUTPUT
Figure 4. PGOOD Pin Behavior
MODE/SYNC Operation
The MODE/SYNC pin is a multipurpose pin allowing both
mode selection and operating frequency synchronization.
ConnectingthispintoINTVCCenablesBurstModeoperation
for superior efficiency at low load currents at the expense
of slightly higher output voltage ripple. When the MODE/
SYNC pin is pulled to ground, forced continuous mode
operation is selected creating the lowest output voltage
ripple at the expense of light load efficiency.
The LTC3626 will detect the presence of an external clock
signalontheMODE/SYNCpinandsynchronizetheinternal
oscillatortothephaseandfrequencyoftheincomingclock.
The presence of an external clock will place the LTC3626
into forced continuous mode operation.
Output Voltage Tracking and Soft-Start
The LTC3626 allows the user to control the output volt-
age ramp rate by means of the TRACK/SS pin. From 0V
to 0.6V the TRACK/SS pin will override the internal refer-
ence input to the error amplifier forcing regulation of the
feedback voltage to that seen at the TRACK/SS pin. When
the voltage at the TRACK/SS pin rises above 0.6V, tracking
is disabled and the feedback voltage will be regulated to
the internal reference voltage.
The voltage at the TRACK/SS pin may be driven from an
external source, or alternatively, the user may leverage the
internal 1.4µA (typical) pull-up current on TRACK/SS to
implement a soft-start function by connecting a capacitor
fromtheTRACK/SSpintoground.Therelationshipbetween
output rise time and TRACK/SS capacitance is given by:
tSS = 430,000 • CTRACK/SS
A default internal soft-start timer forces a minimum soft-
start time of 400µs (typical) by overriding the TRACK/
SS pin input during this time period. Hence, capacitance
valueslessthanapproximately1000pFwillnotsignificantly
affect soft-start behavior.
When using the TRACK/SS pin, the regulator defaults to
Burst Mode operation until the output exceeds 80% of
its final value (VFB > 0.48V). Once the output reaches this
voltage, the operating mode of the regulator switches to
the mode selected by the MODE/SYNC pin as described
Efficiency Considerations
The percent efficiency of a switching regulator is equal to
the output power divided by the input power times 100%.
It is often useful to analyze individual losses to determine
what is limiting the efficiency and which change would
produce the most improvement. Percent efficiency can
be expressed as:
% Efficiency = 100% – (L1 + L2 + L3 +…)
where L1, L2, etc. are the individual loss terms as a per-
centage of input power.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com