| Electronic Components Datasheet Search |
|
GP-MPFC1H21 Datasheet(PDF) 7 Page - Vicor Corporation |
|
|
|||||||||||||||||||||||||||||
GP-MPFC1H21 Datasheet(HTML) 7 Page - Vicor Corporation |
|
7 / 9 page ![]() MIL-COTS PFC Front End Rev 1.3 vicorpower.com Page 7 of 9 01/2014 800 927.9474 Granite Power GP-MPFC1H21 Not Recommended for New Designs PFC Brick Pin function/description LINE/NEUTRAL (Pins 1 & 4) Connect single phase AC mains from appropriate EMI filter to these pins via a 15 Amp 250V fuse. Connect the output of the filter to the LINE and NEUTRAL pins of the PFC Brick. To meet MIL-STD-461E/F requirements, an EMI filter between the AC input and PFC Brick similar to that shown in Fig. 4 is required. N/C (Pins 2, 3, 6, 7) No Connect. Do not connect to these pins. MOD ENABLE (Pin 8) Connect this pin to the down stream Vicor DC/DC converter(s) PC pin as shown in Figure 2. The external circuitry between the MOD ENABLE pin and PC pin shown in the figure must be used to ensure proper operation. During power up, the MOD ENABLE pin is held low until the PFC output is up and regulating. Any fault with the PFC output will cause this pin to go low and held low until the fault is cleared. If an external load is connected directly to the output of the PFC Brick, do not apply the load until the holdup capacitors are fully charged. +/- OUTPUTS (+ Pin 9, - Pin 5) Connect the +OUT pin to the +IN of the respected Vicor DC/DC converter. Connect the -OUT pin to the -IN of the respected Vicor DC/DC converter. In addition, external hold-up capacitor of 1500uF with a minimum voltage rating of 450VDC is required across the +OUT and –OUT pins. This capacitor must be in close proximity of the PFC Brick. Do not exceed 3000uF of total output capacitance. Safety Features: Over Temperature Shut Down: The PFC Brick is designed to shut down if the baseplate temperature (measured in the center of the baseplate) exceeds 100°C. Certain line and load conditions dictate lower maximum temperatures as indicated in Figure 1. Exceeding the power/temperature limits shown in Figure 1 or the maximum 100°C limit may result in permanent module failure. We do not guarantee module survival if the temperature limits are exceeded. The addition of the thermal safety components shown in Figure 2 should be used if the application requires operation at input voltage and output power where a lower baseplate temperature is required. Output Over Voltage Protection: In the event the PFC output exceeds approximately 415VDC, the boost converter will momentarily shut down to keep the PFC output below 415VDC. The MOD Enable pin will go low and stay low until the PFC output returns to its normal operating range. Safety Notes: The PFC Brick is not isolated from the AC mains. An isolation transformer must be used when making scope measurements. The PFC Brick does not provide input to output isolation. Differential probes should be used to avoid destructive ground loops. DESCRIPTION |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |