20 / 28 page ![]() ZL2103 FN6966 Rev 5.00 Page 20 of 28 May 3, 2011 In the ZL2103, the compensation zeros are set by configuring the FC pin or via the I2C/SMBus interface once the user has calculated the required settings. This method eliminates the inaccuracies due to the component tolerances associated with using external resistors and capacitors required with traditional analog controllers. The loop compensation coefficients can also be set via the I2C/SMBus interface. Please refer to Application Note AN2033 for further details. Also refer to Application Note AN2035 for further technical details on setting loop compensation. Driver Dead-time Control The ZL2103 utilizes a predetermined fixed dead-time applied between the gate drive signals for the top and bottom MOSFETs. In a synchronous buck converter, the MOSFET drive circuitry must be operated such that the top and bottom MOSFETs are never in the conducting state at the same time. This is because potentially damaging currents flow in the circuit if both MOSFETs are on simultaneously for periods of time exceeding a few nanoseconds. Conversely, long periods of time in which both MOSFETs are off reduces overall circuit efficiency by allowing current to flow in their parasitic body diodes. Therefore, it is advantageous to minimize the dead-time to provide peak optimal efficiency without compromising system reliability. The ZL2103 has optimized the dead-time for the integrated MOSFETs to maximizing efficiency. Power Management Functional Description Input Undervoltage Lockout The input undervoltage lockout (UVLO) prevents the ZL2103 from operating when the input falls below a preset threshold, indicating the input supply is out of its specified range. The UVLO threshold (VUVLO) can be set to either 4.5V or 10.8V using the SS pin according to Table 6. The UVLO voltage can also be set to any value between 2.85V and 16V via the I2C/SMBus interface. Once an input undervoltage fault condition occurs, the device can respond in a number of ways as follows: 1. Continue operating without interruption. 2. Continue operating for a given delay period, followed by shutdown if the fault still exists. The device will remain in shutdown until instructed to restart. 3. Initiate an immediate shutdown until the fault has been cleared. The user can select a specific number of retry attempts. The default response from a UVLO fault is an immediate shutdown of the device. Please refer to Application Note AN2033 for details on how to configure the UVLO threshold or to select specific UVLO fault response options via the I2C/SMBus interface. Output Overvoltage Protection The ZL2103 offers an internal output overvoltage protection circuit that can be used to protect sensitive load circuitry from being subjected to a voltage higher than its prescribed limits. A hardware comparator is used to compare the actual output voltage (seen at the VSEN pin) to a threshold set to 15% higher than the target output voltage (the default setting). If the VSEN voltage exceeds this threshold, the PG pin will de-assert and the device can then respond in a number of ways as follows: 1. Initiate an immediate shutdown until the fault has been cleared. The user can select a specific number of retry attempts. 2. Turn off the high-side MOSFET and turn on the low-side MOSFET. The low-side MOSFET remains on until the device attempts a restart. The default response from an overvoltage fault is to immediately shut down. For continuous overvoltage protection when operating from an external clock, the only allowed response is an immediate shutdown. Please refer to Application Note AN2033 TABLE 12. RESISTOR SETTING FOR LOOP COMPENSATION G(dB) Qfsw/fn FC (k) 24 0.150 115.000 Open or 11 27 0.150 115.000 Low or 10 27 0.150 69.147 13.3 27 0.150 41.577 14.7 27 0.300 115.000 16.2 27 0.300 69.147 17.8 27 0.300 41.577 19.6 27 0.300 25.000 21.5 27 0.600 69.147 23.7 27 0.600 41.577 26.1 27 0.600 25.000 28.7 30 0.150 115.000 High or 12.1 30 0.150 69.147 31.6 30 0.150 41.577 34.8 30 0.300 115.000 38.3 30 0.300 69.147 42.2 30 0.300 41.577 46.4 30 0.300 25.000 51.1 30 0.600 69.147 56.2 30 0.600 41.577 61.9 30 0.600 25.000 68.1 33 0.150 115.000 75.0 33 0.150 69.147 82.5 33 0.150 41.577 90.9 33 0.300 115.000 100.0 33 0.300 69.147 110.0 33 0.300 41.577 121.0 33 0.300 25.000 133.0 33 0.600 69.147 147.0 33 0.600 41.577 162.0 33 0.600 25.000 178.0 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |