PR2-RSP3-LV-24AC Datasheet(PDF) 3 Page - PHOENIX CONTACT |
|
|
|||||||||||||||||||||||||||||
PR2-RSP3-LV-24AC Datasheet(HTML) 3 Page - PHOENIX CONTACT |
|
3 / 5 page ![]() https://www.phoenixcontact.com/pi/products/2834779 07/23/2018 Page 3 / 5 Relay Module - PR2-RSP3-LV- 24AC/4X21AU - 2834779 Technical data Standards and Regulations EN 50178 Degree of pollution 2 Overvoltage category II Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings Circuit diagram A1 A2 22 12 32 42 24 14 34 44 21 11 31 41 AC coils Diagram Ambienttemperature[°C] 0 0,6 0,8 1 1,2 1,4 1,6 1,8 20 40 60 80 10 30 50 70 Operating voltage range of relay Tu=Tcoil Diagram 0,1 0,2 0,3 0,5 1 2 4 6 10 20 10 20 30 50 70 100 300 200 1 2 1 2 Ohmicload cos =0.4 j Switchingvoltage[V] AC interrupting rating Diagram 0,1 0,2 0,3 0,5 1 2 4 6 10 20 10 20 30 50 70 100 300 200 1 2 3 4 1 2 4 3 L/R<7ms ohmicload ohmicload,2contactsinseries ohmicload,4contactsinseries Switchingvoltage[V] DC interrupting rating |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|