| Electronic Components Datasheet Search |
|
K-MD2-RFB-01F-01 Datasheet(PDF) 17 Page - RFbeam Microwave GmbH |
|
|
|||||||||||||||||||||||||||||
K-MD2-RFB-01F-01 Datasheet(HTML) 17 Page - RFbeam Microwave GmbH |
|
17 / 23 page ![]() © RFbeam Microwave GmbH | Schuppisstrasse 7 | CH-9016 St. Gallen | www.rfbeam.ch | K-MD2 Engineering Sample | data sheet 07/2018 – Revision A | Page 17/23 The table Application commands shows the possible application commands, see the chapter Commands for details. Header Payload Length Description Default INIT 0 Run the initialization sequence and load the configuration files – RSID 4 Radar initial delay [clk] 436 RSSF 4 Radar start frequency [MHz] 24028 RSBW 4 Radar bandwidth [MHz] 194 RSRG 4 Radar receiver gain [dB] 20 PSMC 4 Receivers to include in mean range-doppler map 7 (0b111) PSPT 4 Processor peak detection threshold 1000 PSRC 4 Processor range compensation for threshold 0.0 PSNP 4 Processor maximum number of peaks 200 PSBU 4 Processor background update rate 128 PSBR 4 Processor peak detection minimum range 2 PSTR 4 Processor peak detection maximum range 200 PSBS 4 Processor peak detection minimum speed 0 PSTS 4 Processor peak detection maximum speed 100 PSSM 4 Processor smooth mean range-doppler map 1 PSNT 4 Processor maximum number of tracks to report 20 PSRJ 4 Processor maximum range jitter 2 PSSJ 4 Processor maximum speed jitter 3 PSBL 4 Processor minimum track life 5 PSTL 4 Processor maximum track life 15 PSTH 4 Processor length of history for tracking 10 PSSO 4 Processor report stationary objects 1 PSCS 4 Processor assume constant speed for tracking 1 DSF0 4 Disable messages with given header – DSF1 4 Enable messages with given header – GBYE 0 Disconnect but leave the sensor server running – STOP 0 Stop the sensor server – Table 10: Application commands If a command is rejected a warning will be displayed on the console and in the log file. No response is provided via the network or serial interface to accept or reject the command. The INIT and STOP commands are acknowledged with a DONE message so that the client knows when the command has been completed. When sending the GBYE command the client should read any out- standing messages before disconnecting. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |