24 / 92 page ![]() Sensorless Sinusoidal Drive BLDC Controller A4964 24 Allegro MicroSystems, LLC 955 Perimeter Road Manchester, NH 03103-3353 U.S.A. www.allegromicro.com If ESF = 1 and the A4964 internal junction temperature, TJ, rises above the overtemperature threshold, TJF, the regulator is imme- diately shut down and MRSTn will go low. All A4964 functions other than the regulator remain active. When TJ drops by more than the overtemperature hysteresis below the overtemperature threshold (TJ < TJF – TJHyst), the regulator will remain shut down and MRSTn will remain low for 10 ms. After this timeout, MRSTn goes high and the regulator is re-enabled and attempts to restart. If an undervoltage shutdown and an overtemperature warning occur simultaneously, both must be cleared to allow the regulator to restart. Internal A4964 logic circuitry is not powered from the VLR regu- lator and remains fully operational regardless of whether the VLR regulator is running normally or shut down. A ceramic capacitor of at least 1 µF with an ESR of no more than 250 mΩ should be fitted between the VLR terminal and GND to guarantee stability and oscillation and voltage excursions beyond the specified output voltage range. In some applications, the use of redundant output capacitors may be advisable to avoid such a condition in the event of a single-point capacitor high-impedance failure. PUMP REGULATOR The gate drivers are powered by a programmable voltage internal regulator which limits the supply to the drivers and therefore the maximum gate voltage. At low input supply voltage, the regu- lated supply is maintained by a charge pump boost converter which requires a pump capacitor, typically 470 nF, connected between the CP1 and CP2 terminals. The regulated voltage, VREG, can be programmed to 8 or 11 V and is available on the VREG terminal. The voltage level is selected by the value of the VRG bit. When VRG = 1, the voltage is set to 11 V; when VRG = 0, the voltage is set to 8 V. A suf- ficiently large storage capacitor (see applications section) must be connected to this terminal to provide the transient charging current to the low side drivers and the bootstrap capacitors. Operating Modes The A4964 has two operating modes: SPI mode and stand-alone mode. In SPI mode, it can be fully controlled by a small low-cost external microcontroller through the serial interface. In stand- alone mode, the LIN terminal becomes a PWM input that is used to set the input demand. All configuration settings and basic con- trol functions, except for the demand input, can be programmed through the serial interface in both modes. The demand input can only be set through the serial interface in the SPI mode. SPI MODE When operating in SPI mode (OPM = 0) the demand input is determined by a 10-bit value, input from the external micro- controller. The LIN terminal is a simple LIN physical interface where the data on the LIN bus is interpreted and the responses are provided by the external microcontroller. The only other function that the LIN input provides is to wake the A4964 when it is in the sleep state. STAND-ALONE MODE When operating in stand-alone mode (OPM = 1), the demand input is only determined by the duty cycle of a PWM signal applied to the LIN terminal. The 10-bit demand input through the serial interface is not available in this mode. However, all configuration settings and basic control functions, except for the demand input, can still be programmed through the serial inter- face. In this mode, the LIN input will also wake the A4964 when it is in the sleep state. LOW-POWER SLEEP STATE The A4964 provides a low-power sleep state where the consump- tion from the supply is reduced to a minimum by disabling all normal operation including the charge pump regulator, the inter- nal logic regulator, the external regulator, and the internal clock. In the sleep state, the LIN terminal must be at the same voltage as the supply terminal, VBB, and the IG terminal should be tied to ground to achieve the minimum supply current. There are two sleep states: the normal commanded sleep state and the permanent sleep state. The permanent sleep state is only entered following a watchdog cycle count failure. The state of the A4964 is the same in both cases, but it will only exit the perma- nent sleep state after a power off-on cycle as described in the Microcontroller Watchdog section. When operating in SPI mode (OPM = 0), the A4964 can only be commanded to go into the normal sleep state using the serial interface to change the GTS bit from 0 to 1 when the LIN input is high (recessive). If the LIN input is low (dominant), any sleep command through the serial interface will be ignored, and the GTS bit must be changed to 0 followed by 1 to issue another go- to-sleep command when the LIN input is high (recessive).When operating in stand-alone mode (OPM = 1), the A4964 will go into the normal sleep state using the serial interface to change the GTS bit from 0 to 1, irrespective of the level on the LIN terminal. In stand-alone mode, it will also go to sleep when the IG input |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |