48 / 86 page ![]() Crystalfontz America, Inc. Data Sheet Release Date 2012/02/21 www.crystalfontz.com CFA633-RDI-KU LCD Module (Hardware v2.0 / Firmware u2v1) February 2012 Page 48 type: 0x15 = 2110 valid data_length is 7 or 2 (for turning a slot off) data[0]: display slot (0-7) data[1]: type of item to display in this slot 0 = nothing (data_length then must be 2) 1 = fan tachometer RPM (data_length then must be 7) 2 = temperature (data_length then must be 7) data[2]: index of the sensor to display in this slot: 0-3 are valid for fans 0-31 are valid for temperatures (and the temperature device must be attached) data[3]: number of digits for a fan: 4 digits (0 to 9999) valid fan speed range for a fan: 5 digits (0 to 50000) valid fan speed range for a temperature: 3 digits ( -XX or XXX) for a temperature: 5 digits (-XX.X or XXX.X) data[4]: display column 0-13 valid for a 3-digit temperature 0-12 valid for a 4-digit fan 0-11 valid for a 5-digit fan or temperature data[5]: display row (0-1 valid) data[6]: pulses_per_revolution or temperature units for a fan: pulses per revolution for this fan (1 to 32) for a temperature: units (0 = deg C, 1 = deg F) If a One-Wire CRC error is detected, the temperature will be displayed as "ERR" or "ERROR". If the frequency of the tachometer signal is below the detectable range, the speed will be displayed as "SLOW" or "STOP". Displaying a fan will override the fan power setting to 100% for up to 1/8 of a second every 1/2 second. Please see Fan Connections (Pg. 29) for a detailed description. The return packet will be: type: 0x40 | 0x15 = 0x55 = 8510 data_length = 0 22 (0x16): Send Command Directly to the LCD Controller The controller on the CFA633 is HD44780 compatible. Generally you won’t need low-level access to the LCD controller but some arcane functions of the HD44780 are not exposed by the CFA633’s command set. This command allows you to access the CFA633’s LCD controller directly. Note: It is possible to corrupt the CFA633 display using this command. type: 0x16 = 2210 data_length: 2 data[0]: location code 0 = "Data" register 1 = "Control" register data[1]: data to write to the selected register The return packet will be: type: 0x40 | 0x16 = 0x56 = 8610 data_length = 0 23 (0x17): Configure Key Reporting By default, the CFA633 reports any key event to the host. This command allows the key events to be enabled or disabled on an individual basis. The key events set to report are one of the items stored by the command 4 (0x04): Store Current State As Boot State (Pg. 37). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |