L9474 Datasheet(PDF) 5 Page - STMicroelectronics

Part # L9474
Description  ALL SILICON VOLTAGE REGULATOR
PDF  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  STMICROELECTRONICS [STMicroelectronics]
Direct Link  http://www.st.com
Logo STMICROELECTRONICS - STMicroelectronics

L9474 Datasheet(HTML) 5 Page - STMicroelectronics

  L9474 Datasheet HTML 1Page - STMicroelectronics L9474 Datasheet HTML 2Page - STMicroelectronics L9474 Datasheet HTML 3Page - STMicroelectronics L9474 Datasheet HTML 4Page - STMicroelectronics L9474 Datasheet HTML 5Page - STMicroelectronics L9474 Datasheet HTML 6Page - STMicroelectronics L9474 Datasheet HTML 7Page - STMicroelectronics L9474 Datasheet HTML 8Page - STMicroelectronics  
Zoom Inzoom in Zoom Outzoom out
 5 / 8 page
background image
5/8
L9474
Table 8. Regulation Features
Notes:
5. A 128Hz PWM signal applied to L input, higher than this threshold, will turn on the device.
6. This threshold on the phase signal is used to detect the phase frequency, fIFR, for the Initiation of field regulation.
7. This threshold on the phase signal is used to sense the presence of the phase for fault detection purposes. Furthermore, to prevent
the loss of phase signal, a 31.25% duty cycle is applied to field output when phase drops below Vp2 and Vgo is above setpoint.
8. This is the time duration the L9474 takes to rump up from 0 % to 100% duty cycle in response to an increased load on the gen-
erator. The LRC ratio is set 1:4 and the Vreg comparator status is latched at foundamental frequency rate.
Symbol
Parameter
Test Condition
Min.
Typ.
Max.
Unit
VLON
Lamp term turn on 5 threshold
fL = 128Hz +/-5%
0.65
0.9
1.15
V
ILON
VL = 0.65V
0.3
1.5
mA
VP1
Initiation of regulation detection
phase voltage threshold 6
IP = 1mA (sinking current)
0.35
V
VP2
Fault detection phase voltage
threshold 7
7
89V
IP
Sinking current @ P terminal
VP = 1.5V
0.5
1
1.8
mA
fIFR
Initiation of field regulation
frequency
72
Hz
FSDF
Field Strobe Duty Factor
@ "power up" with fPHASE < fIFR
12.5
%
LRC
Load Response Control rate 8
2.125
2.5
2.875
s
fLRC
LRC transition frequency
LRC disabled above this value
263
310
357
Hz
∆gnd
Difference between ECM &
Alternator ground
-0.2
0.2
V



Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com