| Electronic Components Datasheet Search |
|
A1373LKB Datasheet(PDF) 20 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
A1373LKB Datasheet(HTML) 20 Page - Allegro MicroSystems |
|
20 / 23 page ![]() 20 A1373-DS, Rev. 3 Worcester, Massachusetts 01615-0036 (508) 853-5000 115 Northeast Cutoff, Box 15036 www.allegromicro.com Allegro MicroSystems, Inc. High Precision, Output Pin Programmable, Linear Hall Effect Sensors A1373 and A1374 • A bypass capacitor rated at 0.1μF must be mounted between the VOUT pin and the GND pin during programming. The power supply used for programming should be capable of deliv- ering 28 V and 300 mA. • Before beginning any Blow Fuse mode or Lock Device mode code sequence, the device MUST be reset by cycling VCC power-off and power-on again. Cycling power resets the device by setting all bitfields that have intact fuses to 0. Bitfields with blown fuses are unaffected. In Try Value mode, to retain register settings from previous code sequences, do not cycle power between sequences. When a register is selected in Register Selection mode, when the VPH pulse is sent to enter the Bitfield Selection mode, the bitfields with intact fuses in that register are reset to 0. • In Try Value mode, all bits in the register can be set in one code sequence. For example, setting the binary value 0110 and sending a VPH pulse sets code 6. However, because of the power requirement, blowing fuses must be performed one bitfield at a time. In order to program (blow fuses) for binary 0110, the bitfields MUST be programmed (blown) in two different code sequences:one setting the 0100 bit, and the other setting the 0010 bit (in either order). Power must be cycled before each of the two sequences. • Although a bitfield cannot be reset once its fuse is blown, additional bitfields can be blown at any time, until the device is locked by setting the Lock bit. For example, if bit 1 (0010) has been blown, it is possible to blow bit 0 (0001). Because bit 1 was Programming Guidelines already blown, the end result will be 0011 (code 3). • Before powering down the device after programming, observe the recommended delay, to ensure that the last VPH pulse has decayed before voltage drops to the VPL voltage. This will avoid the generation of overlapping VPL and VPH pulses. At the end of a Lock Device mode code sequence, the delay is not necessary. • Programming order is important in both Try Value mode and in Blow Fuse mode. There will be a slight parametric shift in sensitivity after programming the temperature coefficient, and a slight quiescent voltage shift with polarity. Subsequent changes to sensitivity can cause a shift in the quiescent output voltage. The following order is recommended: a. Polarity b. TC Register c. Sens Coarse d. QVO Coarse e. Sens Fine g. QVO Fine The Clamp Bit register can be programmed at any point in the order, as no parametric shift is observed due to clamps. • The actual distribution of parametric programming ranges are wider than the specified programming ranges, in order to take in to account manufacturing spread. The maximum possible attainable range can be used with the understanding that other specified parameters might be out of datasheet specification in the extended range. (For an example, see the chart Sensitivity Temperature Coefficient Range, in the Typical Characteristics section.) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |