  CL1208-3-100TR-R Datasheet HTML 1Page - Eaton All Rights Reserved. CL1208-3-100TR-R Datasheet HTML 2Page - Eaton All Rights Reserved. CL1208-3-100TR-R Datasheet HTML 3Page - Eaton All Rights Reserved. CL1208-3-100TR-R Datasheet HTML 4Page - Eaton All Rights Reserved. CL1208-3-100TR-R Datasheet HTML 5Page - Eaton All Rights Reserved. CL1208-3-100TR-R Datasheet HTML 6Page - Eaton All Rights Reserved. CL1208-3-100TR-R Datasheet HTML 7Page - Eaton All Rights Reserved. CL1208-3-100TR-R Datasheet HTML 8Page - Eaton All Rights Reserved.  
Zoom Inzoom in Zoom Outzoom out
 2 / 8 page
background image
2
Technical Data
10579
Effective December 2016
CL1208
Multi-phase power inductors
www.eaton.com/electronics
Product specifications
Part Number5
Inductor
Phases
OCL1
(nH)
typical
OCL1
(nH)
minimum
FLL2
(nH)
minimum
I
sat1
2
(A)
DCR (mΩ)
maximum
@ 20 °C
SCL3
(nH) ±20%
I
sat2
4
(A)
CL1208- 2- 100TR-R
2
400
360
320
15
0.45
100
56
CL1208- 3- 100TR-R
3
400
360
320
15
0.45
100
56
CL1208- 4- 100TR-R
4
400
360
320
15
0.45
100
56
CL1208- 6- 100TR-R
6
400
360
320
15
0.45
100
56
1. Open Circuit Inductance (OCL) Test Parameters: 1.0 MHz, 0.1 V
rms, 0.0 Adc, +105 °C
2. Full Load Inductance (FLL) Test Parameters: 1.0 MHz, 0.1 V
rms, Isat1, +105 °C
3. Short Circuit Inductance (SCL) Test Parameters: 1.0 MHz, 0.1 V
rms, 0.0 Adc, +105 °C
CL1208-2-100TR-R short (1 & 4), measure (2 & 3), and divide by 2
CL1208-3-100TR-R short (1 & 4), (3 & 6), measure (2 & 5), and divide by 3
CL1208-4-100TR-R short (1 & 4), (3 & 6), (5 & 8) measure (2 & 7), and divide by 4
CL1208-6-100TR-R short (1 & 4), (3 & 6), (5 & 8), (7 & 10), (9 & 12) measure (2 & 11), and divide by 6
4. I
sat2: Peak current where SCL drops approximately 20% @ +105 °C
8. Part Number Definition: CL1208-x-100TR-R
CL1208 = Product code and size
x= Number of phases
100= Inductance value per phase in nH
TR= Tape and reel packaging
-R suffix = RoHS compliant
Note: This device is licensed for use only when incorporated within a voltage regulator
employing power regulating devices manufactured by Maxim Integrated Devices, Inc.
No license is granted expressly or by implication to use this device with power
regulating devices manufactured by any company other than Maxim.
Dimensions (mm)
Part marking: CL1208-x-100TR-R (x = number of phases), xxxx = lot code
Tolerances are ±0.25 millimeters unless stated otherwise
All soldering surfaces to be coplanar within 0.13 millimeters
PCB tolerances are ±0.1 millimeters unless stated otherwise
DCR measured from point “a” to point “b”
Do not route traces or vias underneath the inductor



Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com