| Electronic Components Datasheet Search |
|
ATW2805S/MSTR Datasheet(PDF) 3 Page - International Rectifier |
|
|
|||||||||||||||||||||||||||||
ATW2805S/MSTR Datasheet(HTML) 3 Page - International Rectifier |
|
3 / 8 page ![]() www.irf.com 3 ATW28XXD Series Notes to Specifications Table I. Electrical Performance Characteristics - continued ATW2812D 1 Parameter guaranteed by line, load and cross regulation tests. 2 Up to 90% of full power is available from either output provided the total output does not exceed 30W. 3 Bandwidth guaranteed by design. Tested for 20KHz to 2MHz. 4 Load current split equally between +V OUT and –VOUT. 5 Three-watt load on output under test, 3 watt to 27 watt load change on other output. 6 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn-on. 7 Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified in Table I. 8 An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 9 Load step transition time between 2 and 10 microseconds. 10 Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1 percent of V OUT at 50 percent load. 11 Input step transition time between 2 and 10 microseconds. 12 Turn-on delay time measurement is for either a step application of power at the input or the removal of ground signal from the inhibit pin (pin 8) while power is applied to the input. Test Symbol Conditions -55°C ≤Tc ≤+125°C Vin = 28 Vdc ±5%, C L = 0 unless otherwise specified Group A Subgroups Device Types Limits Unit Min Max Output response transient step line changes 4, 7, 11 VO TLINE Input step from/to 18 to 40 Vdc, I OUT = 2500mA 4,5,6 All -800 +800 mV pk Recovery time transient step line change 4, 7, 10, 11 TT LINE Input step from/to 18 to 40 Vdc, I OUT = 2500mA 4,5,6 All 4000 µs Turn on overshoot 4 VTon OS I OUT = 0 and 2500mA 4,5,6 All 750 mV pk Turn on delay 4, 12 Ton D I OUT = 0 and 2500mA 4,5,6 All 14 ms Load fault recovery 7 Tr LF 4,5,6 All 14 ms Weight Flange 75 grams |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |