SL2S5002FUD Datasheet(PDF) 13 Page - NXP Semiconductors

Part # SL2S5002FUD
Description  ICODE SLIX-L
PDF  35 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  NXP [NXP Semiconductors]
Direct Link  http://www.nxp.com
Logo NXP - NXP Semiconductors

SL2S5002FUD Datasheet(HTML) 13 Page - NXP Semiconductors

Back Button SL2S5002FUD Datasheet HTML 9Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 10Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 11Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 12Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 13Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 14Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 15Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 16Page - NXP Semiconductors SL2S5002FUD Datasheet HTML 17Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 35 page
background image
SL2S5002_SL2S5102
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.4 — 27 August 2012
193134
13 of 35
NXP Semiconductors
SL2S5002; SL2S5102
ICODE SLIX-L
Option 1 (Option flag set) is supported.
9.4.2.9
LOCK DSFID
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
9.4.2.10
GET SYSTEM INFORMATION
As defined in ISO/IEC 15693-3.
The TAG type of the ICODE SLIX-L IC is “03h”.
9.4.3 Custom commands
The manufacturer code of NXP Semiconductors is defined in ISO/IEC 7816-6A1 (Ref. 5).
It has the value “04h”.
For the structure of custom commands please refer to ISO/IEC 15693-3.
If not explicitly specified differently all address modes are supported.
9.4.3.1
GET RANDOM NUMBER
Command code = B2h
The GET RANDOM NUMBER command is required to receive a random number from the
label IC. The passwords that will be transmitted with the SET PASSWORD command
have to be calculated with the password and the random number (see Section 9.4.3.2
“SET PASSWORD”).
The different passwords are addressed with the password identifier.
Table 7.
Request format
SOF
Flags
GET
RANDOM
NUMBER
IC Mfg
code
UID
CRC16
EOF
-
8 bits
8 bits
8 bits
64 bits
optional
16 bits
-
Table 8.
Response format when Error_flag set
SOF
Flags
Error code
CRC16
EOF
-
8 bits
8 bits
16 bits
-
Table 9.
Response format when Error_flag NOT set
SOF
Flags
Random number CRC16
EOF
-
8 bits
16 bits
16 bits
-



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com