7 / 10 page

475
° Output Timing
SED1600
FR
LP
XSCL
EIO1
EIO2
SEG output
VIH = 0.2 VSS
VIL = 0.8 VSS
tpdEOLLP
VOH = 0.2 VSS
VOL = 0.8 VSS
tpdEOHCL
tpdEOLCL
tpdSLP
tpdSFR
Vn –0.5V
Vn +0.5V
Vn = V0, V2, V3, V5
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
(LP-rise to disable) time
tpdEOLLP
XSCL = “L”
—
—
70
ns
(XSCL-fall to disable) time
tpdEOLCL
LP = “H”
CL = 15 pF
—
—
70
ns
(XSCL-fall to enable) time
tpdEOHCL
—
—
100
ns
(LP-fall to SEG output) time
tpdSLP
V5 = –12.0 to –28.0 V
—
—
4.5
µs
(FR to SEG output) delay time
tpdSFR
CL = 100 pF
—
—
4.5
µs
(VSS = –5.0 V
±10%, Ta = –20 to 85°C)