MODEL NUMBERS
D2425D
D2440D
H12D4825D
H12D4840D
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
24-280
24-280
48-530
48-530
Load Current Range ➂ [Arms]
.15-25
.15-40
.15-25
.15-40
Transient Overvoltage [Vpk]
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC) [ûC/W] ➀
1.02
.63
1.02
.63
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
1620
260
1620
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
10
10
10
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
500
500
500
500
Max. Turn-On Time ➃
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
Max. Turn-Off Time
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS ➀
H12D48XXD
Control Voltage Range
4-15Vdc
Max. Turn-On Voltage
4.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
Nominal Input Impedance
240 Ohms
Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix)
13mA
GENERAL NOTES
➀ All parameters at 25˚C and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on (-10) versions is 0.1 msec.
• Zero Voltage and Random
Turn-On Swi tching
• SCR Output
• Industry Standard Package
• Panel M ount
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 1 OF 2
Two totally independent AC output
relays come in a single standard panel-
mount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zero-
voltage or random turn-on (phase con-
trollable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
Crydom Heat Sinks
offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom's Heat Sink specifica-
tion sheet for all the details.
© 2003 CRYDOM CORP, Specifications subject to change without notice.
D2425DE
D2440DE
H12D4825DE
H12D4840DE
E-SUFFIX
15-32Vdc
15 Vdc
1.0 Vdc
1500 Ohms
15mA
D24XXD
4-15Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13mA
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Dual Relays