| Electronic Components Datasheet Search |
|
1730/INTL Datasheet(PDF) 3 Page - Fluke Corporation |
|
|
|||||||||||||||||||||||||||||
1730/INTL Datasheet(HTML) 3 Page - Fluke Corporation |
|
3 / 6 page ![]() 3 Fluke Corporation Fluke 1730 Three-Phase Electrical Energy Logger Specifications Accuracy Parameter Range Resolution Intrinsic Accuracy at Reference Conditions (% of Reading + % of Full Scale) Voltage 1000 V 0.1 V ± (0.2 % + 0.01 %) Current: Direct input iFlex1500-12 150 A 0.1 A ± (1 % + 0.02 %) 1500 A 1 A ± (1 % + 0.02 %) iFlex3000-24 300 A 1 A ± (1 % + 0.02 %) 3000 A 10 A ± (1 % + 0.02 %) iFlex6000-36 600 A 1 A ± (1.5 % + 0.03 %) 6000 A 10 A ± (1.5 % + 0.03 %) i40s-EL clamp 4 A 1 mA ± (0.7 % + 0.02 %) 40 A 10 mA ± (0.7 % + 0.02 %) Frequency 42.5 Hz to 69 Hz 0.01 Hz ± (0.1 %) Aux input ± 10 V dc 0.1 mV ± (0.2 % + 0.02 %) Voltage Min/Max 1000 V 0.1 V ± (1 % + 0.1 %) Current Min/Max defined by accessory defined by accessory ± (5 % + 0.2 %) Cos ϕ/DPF 0 <= Cos ϕ <=1 0.01 ± 0.025 Power factor 0 <= PF <=1 0.01 ± 0.025 THD on voltage 1000 % 0.1 % ± (2.5 % ± 0.05 %) THD on current 1000 % 0.1 % ± (2.5 % ± 0.05 %) Intrinsic uncertainty ± (% of reading + % of range)1 Parameter Influence quantity iFlex1500-12 iFlex3000-24 iFlex6000-36 i40s-EL 150A/1500A 300A/3000A 600/6000A 4A/40A Active power P PF ≥ 0.99 1.2 % + 0.005 % 1.2 % + 0.0075 % 1.7 % + 0.0075 % 1.2 % + 0.005 % 0.5 <PF <0.99 1.2 % + 7 x (1-PF) +0.005 % 1.2 % + 7 x (1-PF) + 0.0075 % 1.7 % + 7 x (1-PF) + 0.0075 % 1.2 % + 10 x (1-PF) + 0.005 % Apparent power S, S fund. 0 ≤ PF ≤ 1 1.2 % + 0.005 % 1.2 % + 0.0075 % 1.7 % + 0.0075 % 1.2 % + 0.005% Reactive power N, Q fund. 0 ≤ PF ≤ 1 2.5 % of measured apparent power Additional uncertainty in % of range1 U >250 V 0.015 % 0.0225 % 0.0225 % 0.015 % 1Range = 1000 V x Irange Reference conditions: Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 % Input conditions: Cos ϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %. Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10 % of Irange Primary conductor of clamps or Rogowski coil in center position Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |