Back Button IMP34DT05 Datasheet HTML 4Page - STMicroelectronics IMP34DT05 Datasheet HTML 5Page - STMicroelectronics IMP34DT05 Datasheet HTML 6Page - STMicroelectronics IMP34DT05 Datasheet HTML 7Page - STMicroelectronics IMP34DT05 Datasheet HTML 8Page - STMicroelectronics IMP34DT05 Datasheet HTML 9Page - STMicroelectronics IMP34DT05 Datasheet HTML 10Page - STMicroelectronics IMP34DT05 Datasheet HTML 11Page - STMicroelectronics IMP34DT05 Datasheet HTML 12Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 20 page
background image
5
Process recommendations
To ensure a consistent manufacturing process it is strongly advised to comply with following recommendations:
The recommended pick-up area for the IMP34DT05 package must be defined using the worst case (ie. no
device alignment during picking process). This area has been defined considering all the tolerances of the
components involved (reel, package, sound inlet). Picker tolerance shall be considered as well.
To prevent damage to the MEMS membrane or incorrect pick-up and placement, do not pick up the
component on the inlet area
For the package outline please refer to Figure 7. Carrier tape with microphone (top view). Nozzle shape,
size, and placement accuracy are the other key factors to consider when deciding on the coordinates for the
picking.
Device alignment before picking is highly recommended.
A vacuum force greater than 7 psi must be avoided
1 kPa = 0.145 psi (lb/in²) = 0.0102 kgf/cm² = 0.0098 atm
MSL (moisture sensitivity level) Class 3
Maximum of 3 reflow cycles is recommended
All recommended dimensions (device safe-picking area) do not include the pick-and-place equipment
tolerances
Figure 8. Recommended picking area
To have a safe pick-up "by design", ST strongly advises an ad hoc nozzle.
The following picker ensures that the holes for the vacuum and the air stream are ALWAYS away from the
porthole of the device (4 vacuum ports located at each corner of the device).
The recommended nozzle also has a recess, in the form of a cross, which guarantees that the porthole is always
left at atmospheric pressure. By using the recommended nozzle, the membrane will not suffer any sudden air
disturbances during the picking or placing of the devices in the tape and reel.
IMP34DT05
Process recommendations
DS12725 - Rev 3
page 8/20



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com