| Electronic Components Datasheet Search |
|
L7983 Datasheet(PDF) 20 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L7983 Datasheet(HTML) 20 Page - STMicroelectronics |
|
20 / 43 page ![]() 5.6.1 Overcurrent protection (OCP) In normal operation the HS MOS is turned off when the sensed current is equal to programmed current (refer to Figure 2). The maximum available current is limited by the internal OCP (overcurrent protection) comparator, cycle by cycle. The IPK threshold is gradually reduced during the switching period by slope contribution, as shown in Figure 18. Figure 18. Peak current limit IPK ILX TON_min The inductor current is also monitored during LS MOS on-time. This feature, also known as “valley current limitation”, is effective in case of current runaway due to HS MOS minimum on-time limitation and very low VOUT / VIN ratio. This protection can avoid the HS MOS turn-on if the inductor current, sensed during LS MOS on-time, is higher than the IVY threshold (Figure 19). Figure 19. Valley current limit IPK IVY TON_min ILX L7983 Fault management DS13354 - Rev 1 page 20/43 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|