| Electronic Components Datasheet Search |
|
M41T50 Datasheet(PDF) 11 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M41T50 Datasheet(HTML) 11 Page - STMicroelectronics |
|
11 / 23 page ![]() 11/23 M41T50 CLOCK OPERATION The eight byte clock register (see Table 2., page 12) is used to both set the clock and to read the date and time from the clock, in a binary coded decimal format. Reserved0, Seconds, Min- utes, and Hours are contained within the first four registers. Bits D0 through D2 of Register 04h contain the Day (day of week). Registers 05h, 06h, and 07h contain the Date (day of month), Month, and Years. Bit D7 of Register 01h contains the STOP Bit (ST). Setting this bit to a '1' will cause the oscil- lator to stop. When reset to a '0' the oscillator re- starts within one second (typical). Bits D6 and D7 of Clock Register 06h (Century/ Month Register) contain the CENTURY Bit 0 (CB0) and CENTURY Bit 1 (CB1). Bit D6 of Register 0Ch (Alarm Hour Register) con- tains the SQW Open Drain Bit (SQWOD). When this bit is set to '1,' the Square Wave output will be- come an open drain output and require a pull-up resistor. Note: A WRITE to ANY location within the first eight bytes of the clock register (00h-07h), includ- ing the 60Hz Bit and CB0-CB1 Bits will result in an update of the system clock and a reset of the divid- er chain. This could result in an inadvertent change of the current time. These non-clock relat- ed bits should be written prior to setting the clock, and remain unchanged until such time as a new clock time is also written. The eight Clock Registers may be read one byte at a time, or in a sequential block. Provision has been made to assure that a clock update does not occur while any of the eight clock addresses are being read. If a clock address is being read, an update of the clock registers will be halted. This will prevent a transition of data during the READ. Digital Clock Input The M41T50 requires an external square wave clock source of 50Hz or 60Hz (45% to 55% duty cycle) for the clock function. Bit D7 (60Hz bit) of Register 05h (Date Register) is used to select be- tween a 50Hz (60Hz Bit = '0') or a 60Hz (60Hz Bit = '1') clock input frequency signal. The 60Hz Bit defaults to '1' on power-up. TIMEKEEPER® Registers The M41T50 offers 16 internal registers which contain Clock, Alarm, and Flag Registers. The Clock registers are memory locations which con- tain external (user accessible) and internal copies of the data (usually referred to as BiPORT™ TIME- KEEPER cells). The external copies are indepen- dent of internal functions except that they are updated periodically by the simultaneous transfer of the incremented internal copy. The internal di- vider (or clock) chain will be reset upon the com- pletion of a WRITE to any clock address (00h to 07h). The system-to-user transfer of clock data will be halted whenever the address being read is a clock address (00h to 07h). The update will resume ei- ther due to a Stop Condition or when the pointer increments to a non-clock address. TIMEKEEPER and Alarm Registers store data in BCD format. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |