| Electronic Components Datasheet Search |
|
WRPP-CNK-R2 Datasheet(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
WRPP-CNK-R2 Datasheet(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: WRPP WRPP SPECIFICATIONS ES-2222 Rev.3 Page 2/4 http://www.m-system.co.jp/ INPUT SPECIFICATIONS ■ Dry Contact Max. frequency: 100 kHz Input requirements Sensing: 5 V DC / 10 mA Detecting level: OFF: ≥ 3.0 V / ≥ 750 Ω ON: ≤ 2.0 V / ≤ 333 Ω Sensing voltage/current shows the excitation supply to the input terminal and the current value at the time of shortcircuit. Detecting level shows the threshold used to determine ON or OFF status of the pulses and the resistance values of the dry contact of that time. ■ Voltage Pulse Waveform: Square or sine •3.3 V Pulse Max. frequency: 1 MHz Input impedance: Approx. 8 kΩ 100 pF Max. voltage between terminals (pulse): -10 – +15 V Max. voltage between terminals (DC): -5 – +10 V DC Detecting level: VH ≥ 2.0 V, VL ≤ 1.3 V •5 V Pulse Max. frequency: 500 kHz Input impedance: Approx. 14 kΩ 100 pF Max. voltage between terminals (pulse): -10 – +15 V Max. voltage between terminals (DC): -5 – +10 V DC Detecting level: VH ≥ 3.0 V, VL ≤ 2.0 V •12 V, 24 V Pulse Max. frequency: 100 kHz Input impedance: Approx. 20 kΩ Max. voltage between terminals (pulse): -30 – +50 V Max. voltage between terminals (DC): -30 – +50 V DC Detecting level: VH ≥ 7.0 V, VL ≤ 5.0 V ■ RS-422 Line Driver Pulse Maximum frequency: 1 MHz Receiver: Conforms to RS-422 (No receiving resistor incorporated) OUTPUT SPECIFICATIONS ■ Open collector Max. frequency: 100 kHz Rating: 50 V DC @ 100 mA Saturation voltage: 0.12 V DC ■ Voltage Pulse: Rating (3.3, 5 or 12 V) ±20 % Max. frequency ; Load resistance (the lower value of either this or the maximum frequency of the input signal) 3.3 V 1 MHz ; 660 Ω 5 V 500 kHz ; 1 kΩ 12 V 100kHz ; 2.4 kΩ Low level: ≤ 0.5 V ■ RS-422 Line Driver Pulse: Conforms to RS-422 Max. frequency: 1 MHz Output current: ±20 mA INSTALLATION Power Consumption •AC: Approx. 4 VA at 100 V Approx. 5 VA at 200 V Approx. 6 VA at 240 V •DC: Approx. 3 W Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 250 g (0.55 lb) PERFORMANCE Response time delay •3.3 or 5 V voltage pulse or RS-422 line driver pulse: Approx. 0.15 - 0.5 μsec. •12 V voltage pulse or open collector: 0.2 - 2 μsec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output 1 to output 2 to power to ground) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Installation Category II Pollution Degree 2 Input or output 1 or output 2 to power input: Reinforced insulation (300 V) Input to output 1 to output 2: Basic insulation (300 V) RoHS Directive EN 50581 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |