12 / 34 page ![]() ADIS16467 Data Sheet Rev. C | Page 12 of 34 The factory calibration of the accelerometer applies the following correction formulas to the data of each accelerometer: 2 ZC 2 YC 2 XC 32 31 23 21 13 12 Z Y X Z Y X 33 32 31 23 22 21 13 12 11 ZC YC XC ω ω ω p p p p p p b b b a a a m m m m m m m m m a a a 0 0 0 where: aXC, aYC, and aZC are the accelerometer outputs (post calibration). m11, m12, m13, m21, m22, m23, m31, m32, and m33 provide scale and alignment correction. aX, aY, and aZ are the accelerometer outputs (precalibration). bX, bY, and bZ provide bias correction. p12, p13, p21, p23, p31 and p32 provide a point of percussion alignment correction (see Figure 48). ω2XC, ω2YC, and ω2ZC are the square of the gyroscope outputs (post calibration). All of the correction factors in this relationship come from direct observation of the response of each accelerometer at multiple temperatures, over the calibration temperature range (−40°C ≤ TC ≤ +85°C). These correction factors are stored in the flash memory bank, but they are not available for observation or configuration. Register MSC_CTRL, Bit 6 (see Table 105) provides the only user configuration option for the factory calibration of the accelerometers: an on/off control for the point of percussion, alignment function. See Figure 46 for more details on the user calibration options available for the accelerometers. Bartlett Window FIR Filter The Bartlett window finite impulse response (FIR) filter (see Figure 23) contains two averaging filter stages, in a cascade configuration. The FILT_CTRL register (see Table 101) provides the configuration controls for this filter. FROM MEMS SENSOR TO FACTORY CALIBRATION 1 N N n = 1 ω(n) 1 N N n = 1 ω(n) Figure 23. Bartlett Window FIR Filter Signal Path Averaging/Decimating Filter The second digital filter averages multiple samples together to produce each register update. In this type of filter structure, the number of samples in the average is equal to the reduction in the update rate for the output data registers. The DEC_RATE register (see Table 109) provides the configuration controls for this filter. FROM USER CALIBRATION ÷N TO OUTPUT REGISTERS Σ 1 N N n = 1 ω(n) Figure 24. Averaging/Decimating Filter Diagram REGISTER STRUCTURE All communication between the ADIS16467 and an external processor involves either reading the contents of an output register or writing configuration or command information to a control register. The output data registers include the latest sensor data, error flags, and identification information. The control registers include sample rate, filtering, calibration, and diagnostic options. Each user accessible register has two bytes (upper and lower), each of which has a unique address. See Table 8 for a detailed list of all user registers and the corresponding addresses. TRIAXIAL GYROSCOPE TEMPERATURE SENSOR TRIAXIAL ACCELEROMETER OUTPUT REGISTERS CONTROL REGISTERS CONTROLLER SENSOR SIGNAL PROCESSING Figure 25. Basic Operation of the ADIS16467 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |