| Electronic Components Datasheet Search |
|
M1EXS Datasheet(PDF) 5 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M1EXS Datasheet(HTML) 5 Page - M-System Co.,Ltd. |
|
5 / 7 page ![]() MODEL: M1EXS-2 M1EXS-2 SPECIFICATIONS ES-5986 Rev.2 Page 5/7 https://www.m-system.co.jp/ PARAMETER LIST It is available to configure or confirm settings shown below by using front button. Configuring or confirming with PC is available when using M1E configurator software (model: M1ECFG). MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL VALUE Ch1 Setting 01 Lockout setting Lock / Unlock – Lock 06 Ch1 Angle offset – Deg. 0.00 07 Ch1 Angle span 60.00 – 359.99 Deg. 270.00 08 Ch1 Rotating direction CW / CCW – CW 14 Ch1 0 % input scaling -99999 – 999999 – 0.00 15 Ch1 100 % input scaling -99999 – 999999 – 100.00 16 Ch1 Input decimal point No decimal point The number of decimal places: 1 – 5 – 2 places of decimals 17 Ch1 Unit (INP Scaling) Choose from 68 types* – % 18 Ch1 Output range 0 – 20 mA -5 – +5 V -10 – +10 V – 0 – 20 mA 19 Ch1 0 % output setting 0.000 – 19.000 -5.000 – 4.750 -10.000 – 9.000 mA V V 4.000 20 Ch1 100 % output setting 1.000 – 20.000 -4.750 – 5.000 -9.000 – 10.000 mA V V 20.000 28 Ch1 Overrange output < 0 % -5.00 – 0.00 % -5.00 29 Ch1 Overrange output > 100 % -100.00 – 105.00 % 105.00 79 Ch1 Filter time constant 0 – 30 sec. 0 82 Ch1 Output Zero fine adjust -5.000 – 5.000 % 0.000 83 Ch1 Output Span fine adjust 95.000 – 105.000 % 100.000 89 Ch1 Loop test -5.00 – 105.00 % Cancel Ch2 Setting 106 Ch2 Angle offset – Deg. 0.00 107 Ch2 Angle span 60.00 – 359.99 Deg. 270.00 108 Ch2 Rotating direction CW / CCW – CW 114 Ch2 0 % input scaling -99999 – 999999 – 0.00 115 Ch2 100 % input scaling -99999 – 999999 – 100.00 116 Ch2 Input decimal point No decimal point The number of decimal places: 1 – 5 – 2 places of decimals 117 Ch2 Unit (INP Scaling) Choose from 68 types* – % 118 Ch2 Output range 0 – 20 mA -5 – +5 V -10 – +10 V – 0 – 20 mA 119 Ch2 0 % output setting 0.000 – 19.000 -5.000 – 4.750 -10.000 – 9.000 mA V V 4.000 120 Ch2 100 % output setting 1.000 – 20.000 -4.750 – 5.000 -9.000 – 10.000 mA V V 20.000 128 Ch2 Overrange output < 0 % -5.00 – 0.00 % -5.00 129 Ch2 Overrange output > 100 % -100.00 – 105.00 % 105.00 179 Ch2 Filter time constant 0 – 30 sec. 0 182 Ch2 Output Zero fine adjust -5.000 – 5.000 % 0.000 183 Ch2 Output Span fine adjust 95.000 – 105.000 % 100.000 189 Ch2 Loop test -5.00 – 105.00 % Cancel 01 Lockout setting Lock / Unlock – Lock |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |