| Electronic Components Datasheet Search |
|
M1EAXV-2-2-R Datasheet(PDF) 6 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M1EAXV-2-2-R Datasheet(HTML) 6 Page - M-System Co.,Ltd. |
|
6 / 10 page ![]() MODEL: M1EAXV-2 M1EAXV-2 SPECIFICATIONS ES-5995 Rev.2 Page 6/10 https://www.m-system.co.jp/ PARAMETER LIST The following parameters can be set or checked, by the front button operation, or from the PC by using M1EA con guration software (model: M1EACFG). MODE ITEM SETTING PARAMETER RANGE UNIT INITIAL VALUE Ch1 setting 01 Lockout setting Lock / Unlock — Lock 11 Ch1 Input range 0 – 50 mA -1000 – +1000 mV -10 – +10 V — 0 – 50 mA 12 Ch1 0 % input setting 0.00 – 48.00 -1000.0 – 900.0 -10.000 – 9.000 mA mV V 4.00 13 Ch1 100 % input setting 2.00 – 50.00 -900.0 – 1000.0 -9.000 – 10.000 mA mV V 20.00 14 Ch1 0 % input scaling -99999 – 999999 — 0.00 15 Ch1 100 % input scaling -99999 – 999999 — 100.00 16 Ch1 Input decimal point No decimal point The number of decimal places : 1 – 5 — 2 places of decimals 17 Ch1 Unit (INP Scaling) Choose from 68 types* — % 30 Ch1 L1 alarm enable Disable / Enable — Enable 31 Ch1 L1 alarm setpoint -99999 – 999999 * — 20.00 32 Ch1 L1 trip action High / Low — Low 33 Ch1 L1 deadband 0 – 999999* — 0.01 34 Ch1 L1 coil at alarm Energized / De-energized — Energized 40 Ch1 L2 alarm enable Disable / Enable — Enable 41 Ch1 L2 alarm setpoint -99999 – 999999* — 80.00 (2 points alarm) 30.00 (4 points alarm) 42 Ch1 L2 trip action High / Low — High (2 points alarm) Low (4 points alarm) 43 Ch1 L2 deadband 0 – 999999 * — 0.01 44 Ch1 L2 coil at alarm Energized / De-energized — Energized 50 Ch1 L3 alarm enable Disable / Enable — Enable 51 Ch1 L3 alarm setpoint -99999 – 999999 * — 70.00 52 Ch1 L3 trip action High / Low — High 53 Ch1 L3 deadband 0 – 999999 * — 0.01 54 Ch1 L3 coil at alarm Energized / De-energized — Energized 60 Ch1 L4 alarm enable Disable / Enable — Enable 61 Ch1 L4 alarm setpoint -99999 – 999999* — 80.00 62 Ch1 L4 trip action High / Low — High 63 Ch1 L4 deadband 0 – 999999 * — 0.01 64 Ch1 L4 coil at alarm Energized / De-energized — Energized 70 Ch1 Alarm ON-delay time 0 – 999 sec. 0 71 Ch1 Power ON-delay time 0 – 999 sec. 5 72 Ch1 Latching alarm Disable / Enable — Disable 79 Ch1 Filter time constant 0 – 30 sec. 0 80 Ch1 Input Zero ne adjust -5.000 – 5.000 % 0.000 81 Ch1 Input Span ne adjust 95.000 – 105.000 % 100.000 89 Ch1 Alarm test — — Cancel |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |