Back Button M1EAXV-1-A-R Datasheet HTML 2Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 3Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 4Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 5Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 6Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 7Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 8Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 9Page - M-System Co.,Ltd. M1EAXV-1-A-R Datasheet HTML 10Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 7 / 10 page
background image
MODEL: M1EAXV-1
M1EAXV-1 SPECIFICATIONS
ES-6031 Rev.2 Page 7/10
https://www.m-system.co.jp/
MODE
ITEM
SETTING PARAMETER
RANGE
UNIT
INITIAL VALUE
Alarm setting
130
L5 alarm enable
Disable / Enable
Enable
131
L5 alarm setpoint
-99999 – 999999*
60.00
132
L5 trip action
High / Low
High
133
L5 deadband
0 – 999999*
0.01
134
L5 coil at alarm
Energized / De-energized
Energized
140
L6 alarm enable
Disable / Enable
Enable
141
L6 alarm setpoint
-99999 – 999999*
70.00
142
L6 trip action
High / Low
High
143
L6 deadband
0 – 999999*
0.01
144
L6 coil at alarm
Energized / De-energized
Energized
150
L7 alarm enable
Disable / Enable
Enable
151
L7 alarm setpoint
-99999 – 999999*
80.00
152
L7 trip action
High / Low
High
153
L7 deadband
0 – 999999*
0.01
154
L7 coil at alarm
Energized / De-energized
Energized
160
L8 alarm enable
Disable / Enable
Enable
161
L8 alarm setpoint
-99999 – 999999*
90.00
162
L8 trip action
High / Low
High
163
L8 deadband
0 – 999999*
0.01
164
L8 coil at alarm
Energized / De-energized
Energized
70
Alarm ON-delay time
0 – 999
sec.
0
71
Power ON-delay time
0 – 999
sec.
5
72
Latching alarm
Disable / Enable
Disable
89
Alarm test
Cancel
01
Lockout setting
Lock / Unlock
Lock
Advanced
201
Display setting
Upper: choose from 4 types*
Lower: choose from 5 types*
Upper: INPUT (Scaling)
Lower: ALARM
203
Brightness
1 (darkest) – 4 (brightest)
4
204
Display timeout
0 (always on), 1 – 60
min.
10
205
Reset all settings
OFF / RESET
OFF
206
Version indication
01
Lockout setting
Lock / Unlock
Lock
* For details, refer to the operating manual (EM-6031-B).
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]
125 (4.92)
36 (1.42)
45 (1.77)
[4 (.16)]
DIN RAIL
35mm wide
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
* Base does not come with the unit.
Please order separately.



Html Pages

1 2 3 4 5 6 7 8 9 10


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com