| Electronic Components Datasheet Search |
|
M1EAXV-1-B-R Datasheet(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
M1EAXV-1-B-R Datasheet(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 10 page ![]() MODEL: M1EAXV-1 M1EAXV-1 SPECIFICATIONS ES-6031 Rev.2 Page 2/10 https://www.m-system.co.jp/ L4 alarm output to L5 or L6 alarm output to L7 or L8 alarm output to power • Output code C: Input to L1 alarm output to L2 alarm output to L3 alarm output to L4 alarm output to power Configuration: Program with front buttons or Via PC. Programmable features include: Refer to the parameter list. Configurator connection: 2.5 dia. miniature jack; RS-232-C level ■Recommended solderless terminal size - M3 (unit: mm) 12max 3max 4min 3.2 dia. (mm) DISPLAY Display functions: Displays and sets measured range, engineering unit Display size: Approx. 15.6 × 20.8 mm (0.61” × 0.82”) Number of pixels: 68 × 95 (horizontal × vertical) Character color: Yellow (reversing display of the current value and the alarm setting value when alarm is tripped) Display life: Approx. 50000 hours (Expected time for the Display brightness to be reduced to 50 % when the Display is used continuously with brightness setting 2 in 25 ℃) Display type: OEL display Display digit: Negative 5 digits, positive 6 digits (-99999 to 999999) Decimal point position: Selectable INPUT SPECIFICATIONS ■ DC Current Input resistance: Incorporated (28 Ω) Input range: 0 - 50 mA DC Minimum span: 2 mA The measurement available for -5 - +105% of input setting range. ■ DC Voltage •Narrow Spans (mV) Input range: -1000 – +1000 mV DC Minimum span: 100 mV •Wide Spans (V) Input range: -10 – +10 V DC Minimum span: 1 V Input resistance: 1 MΩ minimum The measurement available for -5 - +105% of input setting range. OUTPUT SPECIFICATIONS Relay rating: 100 V AC @ 0.5 A (cos ø = 1) 120 V AC @ 0.5 A (cos ø = 1) 240 V AC @ 0.5 A (cos ø = 1) 30 V DC @ 1 A (resistive load) Maximum switching voltage: 250 V AC or 125 V DC Maximum switching power: 120 VA or 30 W Minimum load: 5 V DC @ 1 mA Mechanical life: 5 × 107 cycles LL L HH H Input % • Example Quad N.O. contacts (LL, L, H, HH) Alarm Trip Operation Trip operation in power failure Output code A: All relays turn OFF. Output code B: All relays turn ON. Output code C: Terminals 13 – 15, 16 – 18, 6 – 12, 1 – 7 turn ON. 0 50 100 ▲ ▲ ▲ ▲ L2 L3 L4 L1 ON ON OFF ON ON OFF OFF OFF INSTALLATION Power consumption •DC: ≤ 6 W Operating temperature: -5 to +55°C (23 to 131°F) Storage temperature: -5 to +55°C (23 to 131°F) Operating humidity: 10 to 85 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 150 g (0.33 lb) except base PERFORMANCE in percentage of FS input Accuracy (display accuracy, setting accuracy): ± (0.1% of FS + 1 digit) See CALCULATION EXAMPLES OF OVERALL ACCURACY. Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time (Filter time constant: 0 sec.): ≤ 0.5 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: • Output code A, B: 1500 V AC @ 1 minute (Input to L1 or L2 alarm output to L3 or L4 alarm output to L5 or L6 alarm output to L7 or L8 alarm output to power to ground) • Output code C: 1500 V AC @ 1 minute (Input to L1 alarm output to L2 alarm output to L3 alarm output to L4 alarm output to power to ground |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |