| Electronic Components Datasheet Search |
|
LTWT Datasheet(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
LTWT Datasheet(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 9 page ![]() MODEL: LTWT LTWT SPECIFICATIONS ES-3355 Rev.18 Page 2/9 https://www.m-system.co.jp/ 4W: -10 – +10 V DC (Load resistance 10 kΩ min.) 5W: -5 – +5 V DC (Load resistance 5000 Ω min.) 0: Specify voltage (See OUTPUT SPECIFICATIONS) [5] PULSE OUTPUT (open collector) 0: None 1: 2.777 Hz at 100 % input 2: Specify pulse unit (within 0.006 – 3.12 Hz) [6] AUXILIARY POWER SUPPLY AC Power K3: 100 – 120V AC (Operational voltage range 85 - 132 V, 47 - 66 Hz) L3: 200 – 240V AC (Operational voltage range 170 - 264 V, 47 - 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) V: 48 V DC (Operational voltage range 48 V ± 10 % , ripple 10 % p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) (CE not available) [7] OPTIONS (multiple selections) Terminal Cover blank: Without /T: With Custom specification (Refer to the custom specification list for difference of specification and combination of code numbers.) blank: none /X1: Input range /X2: Input span Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating GENERAL SPECIFICATIONS Connection: M4 screw terminals (torque 1.2 N·m) Screw terminal: Chrome-plated steel Housing material: Flame-resistant resin (black) Isolation: Voltage input to current input to DC output to pulse output to auxiliary power Computation: Time division multiplication Overrange output: Approx. -10 to +120 % at 1 – 5 V Zero adjustment(DC output): -5 to + 5 % (front) Span adjustment(DC output): 95 to + 105 % (front) INPUT SPECIFICATIONS Frequency: 50 or 60 Hz • Voltage input Operational range: 0 – 120 % of rating Overload capacity: 200 % of rating for 10 sec., 120 % continuous • Current input Operational range: 0 – 120 % of rating Overload capacity: 4000 % of rating for 1 sec., 2000 % for 4 sec., 120 % continuous ■ How to determine Wattage Range Calibration Range [W] = Measuring Wattage ÷ ((VT Ratio) × (CT Ratio)) Check that the required calibration range is within the available range in the table. Specify this range when ordering. [Example] 3-phase / 3-wire, measuring wattage 750 kW, VT 3300/110 V, CT 250/5 A 750 × 103 [W] ÷ ((3300÷110) × (250÷5)) = 500 [W] |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |