4 / 5 page ![]() MODEL: MSP4D MSP4D SPECIFICATIONS ES-4803 Rev.8 Page 4/5 http://www.m-system.co.jp/ ITEM ACCESS FUNCTION RANGE Retry Set / Get Set Retry Times Range: 1 to 255 The actuator tries to restart for the number of preset “Retry” times. Default: 5 IllegalInputOPN Set / Get Illegal Input Operation 0 : Input limit position Set the actuator’s operation in case of an illegal input. 1 : Stop 2 : 0% position 3 : 100% position Default: 0 COMM ErrorOPN Get 0 : Stop Shows the communication error operation setting on the control 1 : 0% position circuit board of the actuator. 2 : 100% position COMM FaultTime Set / Get Set Stand-by Time Before Starting Communication Error Operation Range: 10 to 255 The time to wait in case of an communication error before starting the Default: 10 (sec.) pre-designated operation. Direction Set / Get Set Input Action 0 : Reverse Direct action: 100% output at 0% input 1 : Direct Reverse action: 0% output at 0% input Default: 0 Not related to relations between Present Position (position output) and actual stem position. MIN input Set / Get Position Target Input Limit Range: -50 to 10000 Set the lower limit of “Input as Target.” Default: -50 (×0.01%) Any input below the setpoint is clamped to the set value. MAX input Set / Get Position Target Input Limit Range: 0 to 10050 Set the upper limit of “Input as Target.” Default: 10050 (×0.01%) Any input above the setpoint is clamped to the set value. Input as Zero Set / Get Input Scaling (such as for Split Control) Range: -50 to 10000 “Input as Target” value for 0% output stem position setpoint. Default: 0 (×0.01%) Input as Full Set / Get Input Scaling (such as for Split Control) Range: 0 to 10050 “Input as Target” value for 100% output stem position setpoint. Default: 10000 (×0.01%) DeadlockCNTR Set / Get Deadlock Counter Range: 0 to 65535 (×1) Shows the totalized number of Retries at a deadlock. LastDeadlockPOSN Get Range: -50 to 10050 Shows the output stem position at the last deadlock. (×0.01%) Default: 32767 (invalid data) StartingCNTR *1 Set / Get Motor Starting Counter Range: 0 to 4294967295 Shows the totalized number of starting the motor. (×1) TurnOverCNTR *1 Set / Get Motor Reversing Counter Range: 0 to 4294967295 Shows the totalized number of reversing the motor direction. (×1) Accumulated MVT Set / Get Accumulated Running Distance Range: 0 to 4294967295 * Shows the acculated running distance. 100% span defined with Zero (×0.1%) and Span adjustments on the PCB. * Data stored every 10 minutes. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |