| Electronic Components Datasheet Search |
|
R3-SPA8 Datasheet(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-SPA8 Datasheet(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 5 page ![]() MODEL: R3S-PA8 R3S-PA8 SPECIFICATIONS ES-8935 Rev.6 Page 2/5 http://www.m-system.co.jp/ (ON/OFF time ≥ 5 msec.) This unit is designed to be able to accept a frequency up to 100 Hz, however,‘chattering’ contact must be avoided for accurate measuring of such high frequency. Use mercury relays or similar ones that do not cause any chattering. Totalized pulse range: 0 - 9999999 Count at overflow: Reset and restart at ‘0.’(Max. pulse range selectable from 10000 to 2147483647 using the R3CON PC Configurator Software. ‘0’ or ‘1’ from which restart counting at overflow is pre-settable. Refer to the R3CON Users Manual for detailed information.) ■ INTERNAL EXCITATION Sensing voltage: 13 V DC (max. 24 V with no load) ON voltage: ≥ 9 V (≤ 1.5 kΩ) OFF voltage: ≤ 4.5 V (≥ 18 kΩ) INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 200 g (0.44 lb) PERFORMANCE Data allocation: 16 Current consumption: 70 mA Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (input to internal bus or internal power) 2000 V AC @ 1 minute (power input to FG; isolated on the power supply module) COUNT RESET There are three different ways to reset count value. ■ COUNT RESET WITH DIP SW 1) Remove Network Module or its cables and interrupt communication with other devices. 2) Turn ON the Count Reset SW (DIP SW3-1) on R3S-PA8 module. 3) Return the module to the base and turn the power supply on. 4) ERR LED turns on and the module starts resetting its counter. When the resetting is complete, the LED turns to green. DO NOT remove the power while the red LED is on. 5) After confirming that ERR LED is green, turn the power supply off. 6) Turn OFF the Count Reset SW (DIP SW3-1). 7) Return the Network module onto the base and turn the power supply on. Note: Count Reset SW must be turned OFF after this procedure because the module does not start counting with ON state. Even when the count overflow set value is 1, the counter is reset to 0. ■ COUNT RESET WITH RESET SIGNAL With the Count Reset Input SW (DIP SW3-3) turned ON, the count reset signal value becomes effective. SW3-3 = OFF: invalid SW3-3 = ON: valid One pulse supplied at the Count reset input terminal will be recognized as a reset signal. 1) ERR LED turns on (red color) when the reset signal is received. 2) In 1 second, the module starts resetting its counter. When the resetting is complete, the LED turns to green. 3) After 1 second, ERR LED turns back to the state before the reset signal has been received. Note: Reset signals received while the module is processing (1) through (3) are ignored. Even when the count overflow set value is 1, the counter is reset to 0. ■ COUNT RESET FROM HOST PC/PLC Refer to “COUNTER SETTING FROM HOST PC/PLC” section hereafter. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |