| Electronic Components Datasheet Search |
|
R3S-RS4AS/Q Datasheet(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3S-RS4AS/Q Datasheet(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 4 page ![]() MODEL: R3S-RS4A R3S-RS4A SPECIFICATIONS ES-8936 Rev.5 Page 1/4 http://www.m-system.co.jp/ Remote I/O R3 Series RTD INPUT MODULE (high accuracy, 4 points, isolated, tension clamp terminal block) 27.5 (1.08) 130 (5.12) mm (inch) 120 (4.72) MODEL: R3S-RS4A[1][2] ORDERING INFORMATION • Code number: R3S-RS4A[1][2] Specify a code from below for each of [1] and [2]. (e.g. R3S-RS4AW/Q) • Specify the specification for option code /Q (e.g. /C01/SET) NO. OF CHANNELS 4A: 4 channels, high accuracy [1] COMMUNICATION MODE S: Single W: Dual [2] OPTIONS blank: none /Q: Options other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating EX-FACTORY SETTING /SET: Preset according to the Ordering Information Sheet (No. ESU-8345) GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Input: Separable tension clamp terminal (applicable wire size: 0.2 to 1.5 mm2, stripped length 10 mm) Internal power: Via the Installation Base (model: R3-BSx) Isolation: Input 1 to input 2 to input 3 to input 4 to internal bus or internal power Sensor type: Selectable with the side DIP SW Temperature unit: °C or °F selectable with the side DIP SW Conversion rate: Selectable with the side DIP SW Burnout detection: Upscale or downscale selectable with the side DIP SW Linearization: Standard RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Bi-color (red/green) LED; Red with burnout; Green in normal operating conditions. INPUT SPECIFICATIONS Maximum leadwire resistance: 10 Ω per wire Sensing current: ≤ 0.5 mA Temperature range RTD °C CONFORMANCE RANGE (°C) BURNOUT VALUE (°C × 100) Pt 100 (JIS ’97, IEC) Pt 100 (JIS ’89) JPt 100 (JIS ’89) Pt 1000 RTD Pt 100 (JIS ’97, IEC) Pt 100 (JIS ’89) JPt 100 (JIS ’89) Pt 1000 -50 to +200 -50 to +200 -50 to +200 -50 to +200 -24000, +32767 -24000, +32767 -23600, +32767 -24000, +32767 °F CONFORMANCE RANGE (°F) BURNOUT VALUE (°F × 10) -58 to +392 -58 to +392 -58 to +392 -58 to +392 -4000, +6218 -4000, +6218 -3928, +6218 -4000, +6218 INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 200 g (0.44 lb) PERFORMANCE Conversion accuracy: ±0.2°C or ±0.4°F Conversion rate: 250 msec. or 1 sec. selectable Data range °C: Engineering unit value × 100 (integer) °F: Engineering unit value × 10 (integer) Data allocation: 4 Current consumption: 70 mA |
Similar Part No. - R3S-RS4AS/Q |
|
Similar Description - R3S-RS4AS/Q |
|
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |