2 / 5 page ![]() MODEL: R3-WT1A R3-WT1A SPECIFICATIONS ES-8416 Rev.5 Page 2/5 http://www.m-system.co.jp/ INPUT SPECIFICATIONS Frequency: 50 or 60 Hz • Voltage Input Operational range: 0 – 120 % of rating Overload capacity: 150 % of rating for 10 sec., 120 % continuous • Current Input Range CLSA-08: 0 – 80 A AC CLSA-12: 0 – 120 A AC Operational range: 0 – 115 % of rating Be sure that the input voltage is of 440 V or less. ■ Power Factor Input Range: -1 – lag 0 – 1 – lead 0 – -1 Data range: -1000 – 0 – 1000 – 0 – -1000 with SW2-1 set to OFF A device which employs different measuring methods may show different outputs from that of M-System's. ■ Frequency Input Range: 45 – 65 Hz Data range: 4500 – 6500 ACTIVE / REACTIVE POWER INPUT RANGE •Single-phase/2-wire INPUT USABLE RANGE VT BURDEN (VA) 110V / 80A ±8800W 0.2/phase 110V / 120A ±13200W 220V / 80A ±17600W 0.4/phase 220V / 120A ±26400W •Single-phase/3-wire INPUT USABLE RANGE VT BURDEN (VA) 200V / 80A ±16000W 0.2/phase 200V / 120A ±24000W •3-phase/3-wire INPUT USABLE RANGE VT BURDEN (VA) 110V / 80A ±15240W / lead 15240 var lag 0.2/phase 110V / 120A ±22860W / lead 22860 var lag 220V / 80A ±30480W / lead 30480 var lag 0.4/phase 220V / 120A ±45730W / lead 45730 var lag Reactive power data in Lead: Positive, Lag: Negative Note: Reactive power is invalid in single-phase systems. Choose VT ratio so that the calibration range calculated by the following equation is within the usable range in the above table. Calibration Range [W] = Measuring Wattage [W] (VT Ratio) × (Current Rating) INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 300 g (0.66 lb) PERFORMANCE Accuracy (at 23°C ±10°C or 73.4°F ±18°F, 45 – 65 Hz) (Except the sensor’s accuracy.) Active / reactive power: ±2 % (Add sensor’s accuracy for overall performance) Power factor: ±4 % (Add sensor’s accuracy for overall performance) Frequency: ±1 % Active / reactive energy: ±2 % (Add sensor’s accuracy for overall performance) Magnetic field (ext. origin) effect: ± 0.5 % (400 A/m) Conversion rate: 100 msec. Conversion data: 16 bits / 32 bits Data allocation: 4, 8 or 16 selectable Current consumption: 150 mA Response time: ≤ 2 sec. (0 – 100 % ±1 %) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (voltage input to current input or internal bus or internal power) 2000 V AC @ 1 minute (power input to FG; isolated on the power supply module) |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |