| Electronic Components Datasheet Search |
|
R8-DCM16ALH/Q Datasheet(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R8-DCM16ALH/Q Datasheet(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 6 page ![]() MODEL: R8-DCM16ALH http://www.m-system.co.jp/ R8-DCM16ALH SPECIFICATIONS ES-9746 Rev.3 Page 3/6 OPERATING MODE SETTING (*) Factory setting ■ MODULE ADDRESS Module address can be set with SW1-1 through 1-4 for the tens, and SW1-5 through 1-8 for the ones place digit. Address is selected between 0 to 31. (Factory setting: 0) MODULE ADDRESS SW1 1 5 2 6 3 7 4 8 0 OFF OFF OFF OFF 1 OFF OFF OFF ON 2 OFF OFF ON OFF 3 OFF OFF ON ON 4 OFF ON OFF OFF 5 OFF ON OFF ON 6 OFF ON ON OFF 7 OFF ON ON ON 8 ON OFF OFF OFF 9 ON OFF OFF ON ■ INTERLOCK COMMUNICATION LOGIC REVERSAL Setting internal communication bus logic. Interlock Communication Logic Reversal SW2-1 Interlock function setting off: 1 Interlock function setting on: normal = 1, interlock = 0 ON Interlock function setting off: 0 (*) Interlock function setting on: normal = 0, interlock = 1 OFF Caution: 1 and 0 values are validated as logic through internal communication bus logic. ■ OUTPUT AT THE LOSS OF COMMUNICATION Setting for all output. OUTPUT AT THE LOSS OF COMMUNICATION SW2-5 Output Hold (*) (last data correctly rerceived is hold OFF Stop output (Output xed at OFF) ON ■ TERMINATOR DIP SW TERMINATOR SW SW2-6 Without (*) OFF With ON ■ CONFIGURATION MODE CONFIGURATION MODE SW2-8 DIP switch setting (*) OFF PC ON Caution: SW2-2 through 2-4 and 2-7 are unused; be sure to turn OFF unused channels. ■ FULL INTERLOCK FUNCTION It is available to apply full interlock function to all outputs (Do1 through Do16) Full Interlock Function SW3-1 OFF OFF ON (*) (all outputs OFF if input OFF) ON Caution: SW3-2 is unused; be sure to turn OFF unused channels. ■ PARTIAL INTERLOCK • Partital interlock function 1 PARTIAL INTERLOCK 1 SW4 1 OFF OFF ON (*) (Input OFF with output OFF) ON • Partital interlock function 2 SW5 1 OFF OFF ON (*) (Input OFF with output OFF) ON At output, it is available to apply interlock function to Do1 though Do8. At output, it is available to apply interlock function to Do9 though Do16. PARTIAL INTERLOCK 2 Caution: SW4-2 and 5-2 are unused; be sure to turn OFF unused channels. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |