| Electronic Components Datasheet Search |
|
OPT3004DNPR Datasheet(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
OPT3004DNPR Datasheet(HTML) 21 Page - Texas Instruments |
|
21 / 47 page ![]() A series of result register output examples with the corresponding LSB weight and resulting lux are given in Table 8-9. Note that many combinations of exponents (E[3:0]) and fractional results (R[11:0]) can map onto the same lux result, as shown in the examples of Table 8-9. Table 8-9. Examples of Decoding the Result Register into lux RESULT REGISTER (Bits 15:0, Binary) EXPONENT (E[3:0], Hex) FRACTIONAL RESULT (R[11:0], Hex) LSB WEIGHT (lux, Decimal) RESULTING LUX (Decimal) 0000 0000 0000 0001b 00h 001h 0.01 0.01 0000 1111 1111 1111b 00h FFFh 0.01 40.95 0011 0100 0101 0110b 03h 456h 0.08 88.80 0111 1000 1001 1010b 07h 89Ah 1.28 2818.56 1000 1000 0000 0000b 08h 800h 2.56 5242.88 1001 0100 0000 0000b 09h 400h 5.12 5242.88 1010 0010 0000 0000b 0Ah 200h 10.24 5242.88 1011 0001 0000 0000b 0Bh 100h 20.48 5242.88 1011 0000 0000 0001b 0Bh 001h 20.48 20.48 1011 1111 1111 1111b 0Bh FFFh 20.48 83865.60 Note that the exponent field can be disabled (set to zero) by enabling the exponent mask (configuration register, ME field = 1) and manually programming the full-scale range (configuration register, RN[3:0] < 1100b (0Ch)), allowing for simpler operation in a manually-programmed, full-scale mode. Calculating lux from the result register contents only requires multiplying the result register by the LSB weight (in lux) associated with the specific programmed full-scale range (see Table 8-8). See the Low-Limit Register for details. See the configuration register conversion time field (CT, bit 11) description for more information on lux resolution as a function of conversion time. 8.6.2.2 Configuration Register (offset = 01h) [reset = C810h] This register controls the major operational modes of the device. This register has 11 fields, which are documented below. If a measurement conversion is in progress when the configuration register is written, the active measurement conversion immediately aborts. If the new configuration register directs a new conversion, that conversion is subsequently started. Figure 8-6. Configuration Register 15 14 13 12 11 10 9 8 RN3 RN2 RN1 RN0 CT M1 M0 OVF R/W R/W R/W R/W R/W R/W R/W R 7 6 5 4 3 2 1 0 CRF FH FL L POL ME FC1 FC0 R R R R/W R/W R/W R/W R/W LEGEND: R/W = Read/Write; R = Read only Table 8-10. Configuration Register Field Descriptions Bit Field Type Reset Description 15:12 RN[3:0] R/W 1100b Range number field (read or write). The range number field selects the full-scale lux range of the device. The format of this field is the same as the result register exponent field (E[3:0]); see Table 8-8. When RN[3:0] is set to 1100b (0Ch), the device operates in automatic full-scale setting mode, as described in the Automatic Full-Scale Setting Mode section. In this mode, the automatically chosen range is reported in the result exponent (register 00h, E[3:0]). The device powers up as 1100 in automatic full-scale setting mode. Codes 1101b, 1110b, and 1111b (0Dh, 0Eh, and 0Fh) are reserved for future use. www.ti.com OPT3004 SBOS929A – DECEMBER 2018 – REVISED DECEMBER 2021 Copyright © 2021 Texas Instruments Incorporated Submit Document Feedback 21 Product Folder Links: OPT3004 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |