| Electronic Components Datasheet Search |
|
ATTP1A Datasheet(PDF) 2 Page - Analog Technologies, Inc. |
|
|
|||||||||||||||||||||||||||||
ATTP1A Datasheet(HTML) 2 Page - Analog Technologies, Inc. |
|
2 / 8 page ![]() 1161 Ringwood Ct, #110, San Jose, CA 95131, U. S. A. Tel.: (408) 748-9100, Fax: (408) 770-9187 www.analogtechnologies.com Copyrights 2000-2022, Analog Technologies, Inc. All Rights Reserved. Updated on 1/29/2022 Email: staff@analogti.com/sales@analogti.com 2 Analog Technologies ATTP1A Temperature Plate Assembly MAIN FEATURES Large platform for thermal load: 66mm × 44mm Wide temperature regulation range: –20°C to 110°C Accurate temperature stability: 1.8mV Response to large set-point temperature change: 20s from 10 °C to 20°C Response to small set-point temperature change: 6s from 20°C to 21°C High thermal load capability: 15.75W APPLICATIONS It's widely used for evaluating TEC controllers, TECs and heat sink, etc. Also, it can stabilize an object’s temperature for scientific experiments. DESCRIPTION ATTP1A is designed for evaluating TEC controllers, which can be easily evaluated by using this temperature plate. ATTP1A aims to automatically adjust the temperature parameters based on the requested temperature range so that the TEC controller can detect the pre-set temperature range. Temperature plate ATTP1A works together with TEC controller evaluation board and TEC controller. Figure 2 shows the physical photo of ATTP1A. The TEC evaluation board connects with ATTP1A through CON1. On the right side of ATTP1A, it connects with a TEC module, a thermistor, a fan and a heat sink, see Figure 1. R1 (W11, W12, R1A), R2 (W21, W22, R2A), R3 (W31, W32, R3A) are TEC temperature control parameters, see Figure 2. Required temperature parameters can be achieved through adjusting R1, R2 and R3, thus the TEC controller can detect the temperature range that users require. In different temperature ranges, R1, R2 and R3 have different corresponding resistances. R1, R2 and R3 can be determined by: MID HIGH LOW HIGH LOW HIGH LOW MID MID R R R R R R R R R R * 2 * * 2 ) ( 1 − + − + + = MID R R R − = 1 2 MID LOW MID LOW R R R R R R R − − + = ) 1 ( 1 3 Where RHIGH is the resistance of RTH in the highest temperature of the set temperature range; RMID is the resistance of RTH in the medium temperature of the set temperature range; RLOW is the resistance of RTH in the lowest temperature of the set temperature range. For example, set the highest temperature 35°C and the lowest temperature 15°C, so the medium value is 25°C. In the R-T table, RHIGH, RMID and RLOW can be achieved, see Table 2. RHIGH = 6.5k; RMID = 10k; RLOW = 15.7k In accordance with the above three formulas, R1, R2 and R3 can be calculated: R1=18.14k; R2=8.14k; R3=75.87k As shown in Figure 4, R1 is equal to the sum of W11 (potentiometer), W12 (potentiometer) and R1A (fixed value resistor), that is, R1=W11+W12+R1A. So simply adjust W11 and W12, R1 will be 8.051k. W11 provides coarse adjustment and W12 provides fine adjustment. The same goes to R2 and R3, that is: R2=W21+W22+R2A R3=W32+W33+R3A Where W21 and W31 provide coarse tuning; W22 and W32 provide fine tuning. At the bottom right side of the plate, there are three switches S1, S2, and S3, which can be used to adjust the temperature parameters. When adjusting R1, R2 and R3, disconnect them with circuit (turn corresponding switch to OUT), thus the measured R1, R2 and R3 are available. When R1, R2 and R3 are all adjusted to the required resistance, turn on all switches (switch to IN). Solder pad TP11 and TP12 are test points of R1. When the switch is off, use resistance function of the multimeter and connect its two test leads to TP11 and TP12. At this time, adjust W11 and W12, the resistance of R1 can be read in the meter. Users can tune R1 on the basis of calculated temperature parameters and get the required resistance from the multimeter. This method is also applied to R2 and R3. TP21 and TP22 can be used to test R2; TP31 and TP32 can be used to test R3. There are solder joints on the sides of the board. These solder joints can be used to connect with external devices or components. Test lines of other devices can be placed into the holes of solder pads directly. Note: It’s recommended to set a narrow temperature range, such as 20°C to 30°C; otherwise, the relationship between the TEMP and the actual temperature is not linear. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |