6 / 8 page ![]() 3. Loosen hex head screws on filter cover. Turn cover to clear screws, remove cover. 4. Pull filter element from the filter head. a) Replace the synthetic or Microglass elements. Verify correct element replacement. b) Wire mesh elements can be cleaned. Ultrasonic cleaners provide best results. 5. Install element in filter housing. Make sure element o-rings seat properly into the head, making sure that the notch on the element lines up with the notch in the head. 6. Inspect the cover o-ring and replace if necessary. 7. Replace cover and tighten hex head screws until they are snug. Do not over-torque (16 - 19 Ft. Lbs.) these screws. Do not interchange the inlet filter cover with the outlet filter cover. (The inlet filter has a “RFP” prefix, the outlet filter has a “ILP” prefix). 8. Contact the HFD service department at 419-644-0259 regarding iPD calibration. 9. iPD removal: remove oil lines from the iPD at the two fittings closest to the iPD. Disconnect the two cables from the iPD. Remove iPD from cart via two screws. The cart can be used without the iPD as long as the sample hoses are removed from the System 20. Protect sampling connectors from contamination. Assembly 1. Install hoses to inlet and outlet filters by threading the hose end with the straight thread o-ring seal fitting into the filter flange. 2. Connect the PVC tube wands to the swivel fitting on the hose end. When servicing the PVC tube wand, do not over-torque the metal fittings going into the PVC coupling. Over-torque will result in cracking the coupling. Generally, 1/4 turn beyond hand- tight is sufficient. 3. The Intelli-Cart™ is shipped with a bag that contains user manuals, iPD programming disk, and accessory parts. 4. The iPD is shipped with the factory default setting. Users can reprogram the iPD with the cable located in the attached bag, the program disk and the iPD owners manual. Operating Instructions 1. Insert the inlet wand assembly into the supply fluid receptacle (drum/reservoir). The RFP filter is the inlet filter. 2. Insert the outlet wand assembly into the clean fluid receptacle (drum/reservoir). The ILP fIlter is the outlet filter. 3. Verify that the ON/OFF switch is OFF and plug the cord into the proper grounded power source (3 wire). 4. Turn switch to ON position and check outlet wand for oil flow. Allow 30 to 60 seconds for filters to fill with oil. If repeated attempts to obtain oil flow fail, check pump inlet fittings for tightness, remove inlet filter access cover and verify the cover sealing o-ring is in place. For very viscous fluids it may be necessary to pour 1 or 2 quarts of fluid into the RFP inlet filter housing to prime pump initially. 5. The condition of the filter element should be monitored by observing the cleanliness indicator on the outlet filter. When the indicator is in the CHANGE position, both inlet and outlet filter elements MUST be replaced to prevent fluid from going through the bypass in the filters. 6. The inlet filter element is pro- vided with a 3PSI bypass spring, and prevents the pump from cavitating if the element is not changed. The outlet filter ele- ment is provided with a 35PSI bypass spring to prevent exces- sive pressure which may be harmful to personnel or to the filter cart. Warning: The filter bypass spring acts as a relief valve for the pump. Do not restrict the outlet hose with a shut-off valve which will defeat the function of the bypass valve, causing excessive pressure, which may be harmful to personnel or to the filter cart. 7. The cleanliness indicator works on differential pressure and will indicate the condition of the element (CLEAN, CHANGE, or BYPASS). NOTE: The filter cart must be in operation for the indicator to read properly. Maintenance Instructions 1. Turn switch to OFF position and unplug cord from electrical outlet. 2. Remove tube wands from oil to prevent siphoning. Problem Cause Solution Does not start • ON/OFF Switch • No electrical power • Defective motor • Turn switch ON, replace switch if defective • Plug in cart • Replace No oil flow or erratic pump noise • Filter housing not filled with oil • Allow pump to run 30 to 60 seconds • Suction leak • Check tightness of inlet fittings • Check o-ring in inlet filter cover for nicks • Kink or restriction in inlet hose • Add 1 or 2 quarts of oil to inlet filter • Defective pump • Replace pump Indicator reads CHANGE or BYPASS • Element dirty • Oil extremely cold or viscous • Replace or clean elements (both filters) • Change element to coarser micron rating Indicator does not seem to move • No outlet element • 40 micron element installed in outlet filter • Install element • Check cart model number to verify correct element. The inlet filter has a rating RFP prefix; the outlet filter has an ILP prefix 171 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |