Electronic Components Datasheet Search
  New Zealand  ▼
ALLDATASHEET.CO.NZ

X  

74HC193 Datasheet(PDF) 2 Page - NXP Semiconductors

Part # 74HC193
Description  Presettable synchronous 4-bit binary up/down counter
PDF  13 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  PHILIPS [NXP Semiconductors]
Direct Link  http://www.nxp.com
Logo PHILIPS - NXP Semiconductors

74HC193 Datasheet(HTML) 2 Page - NXP Semiconductors

  74HC193 Datasheet HTML 1Page - NXP Semiconductors 74HC193 Datasheet HTML 2Page - NXP Semiconductors 74HC193 Datasheet HTML 3Page - NXP Semiconductors 74HC193 Datasheet HTML 4Page - NXP Semiconductors 74HC193 Datasheet HTML 5Page - NXP Semiconductors 74HC193 Datasheet HTML 6Page - NXP Semiconductors 74HC193 Datasheet HTML 7Page - NXP Semiconductors 74HC193 Datasheet HTML 8Page - NXP Semiconductors 74HC193 Datasheet HTML 9Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 13 page
background image
December 1990
2
Philips Semiconductors
Product specification
Presettable synchronous 4-bit binary
up/down counter
74HC/HCT193
FEATURES
• Synchronous reversible 4-bit binary counting
• Asynchronous parallel load
• Asynchronous reset
• Expandable without external logic
• Output capability: standard
• ICC category: MSI
GENERAL DESCRIPTION
The 74HC/HCT193 are high-speed Si-gate CMOS devices
and are pin compatible with low power Schottky TTL
(LSTTL). They are specified in compliance with JEDEC
standard no. 7A.
The 74HC/HCT193 are 4-bit synchronous binary up/down
counters. Separate up/down clocks, CPU and
CPD respectively, simplify operation. The outputs change
state synchronously with the LOW-to-HIGH transition of
either clock input. If the CPU clock is pulsed while CPD is
held HIGH, the device will count up. If the CPD clock is
pulsed while CPU is held HIGH, the device will count down.
Only one clock input can be held HIGH at any time, or
erroneous operation will result. The device can be cleared
at any time by the asynchronous master reset input (MR);
it may also be loaded in parallel by activating the
asynchronous parallel load input (PL).
The “193” contains four master-slave JK flip-flops with the
necessary steering logic to provide the asynchronous
reset, load, and synchronous count up and count down
functions.
Each flip-flop contains JK feedback from slave to master,
such that a LOW-to-HIGH transition on the CPD input will
decrease the count by one, while a similar transition on the
CPU input will advance the count by one.
One clock should be held HIGH while counting with the
other, otherwise the circuit will either count by two’s or not
at all, depending on the state of the first flip-flop, which
cannot toggle as long as either clock input is LOW.
Applications requiring reversible operation must make the
reversing decision while the activating clock is HIGH to
avoid erroneous counts.
The terminal count up (TCU) and terminal count down
(TCD) outputs are normally HIGH. When the circuit has
reached the maximum count state of 15, the next
HIGH-to-LOW transition of CPU will cause TCU to go
LOW.
TCU will stay LOW until CPU goes HIGH again, duplicating
the count up clock.
Likewise, the TCD output will go LOW when the circuit is in
the zero state and the CPD goes LOW. The terminal count
outputs can be used as the clock input signals to the next
higher order circuit in a multistage counter, since they
duplicate the clock waveforms. Multistage counters will not
be fully synchronous, since there is a slight delay time
difference added for each stage that is added.
The counter may be preset by the asynchronous parallel
load capability of the circuit. Information present on the
parallel data inputs (D0 to D3) is loaded into the counter
and appears on the outputs (Q0 to Q3) regardless of the
conditions of the clock inputs when the parallel load
(PL) input is LOW. A HIGH level on the master reset (MR)
input will disable the parallel load gates, override both
clock inputs and set all outputs (Q0 to Q3) LOW. If one of
the clock inputs is LOW during and after a reset or load
operation, the next LOW-to-HIGH transition of that clock
will be interpreted as a legitimate signal and will be
counted.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com