| Electronic Components Datasheet Search |
|
DA7219 Datasheet(PDF) 57 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
DA7219 Datasheet(HTML) 57 Page - Renesas Technology Corp |
|
57 / 129 page ![]() DA7219 Audio Codec with Advanced Accessory Detect Datasheet Revision 3.4 24-Dec-2021 CFR0011-120-00 57 of 128 © 2021 Renesas Electronics 11.6.5 Example Calculation of the Feedback Divider Setting A codec is operating with Fs (sample rate) = 48 kHz and a reference input clock frequency of 12.288 MHz. The required output frequency = 98.304 MHz. The reference clock input = 12.288 MHz, which falls in the range 10 MHz to 20 MHz, so pll_indiv will be set to 0b010 (dividing the reference input frequency by four, see Table 43. The formula for calculating the feedback divider is: Feedback divider (F) = (VCO output frequency * input divider (pll_indiv)) / reference input clock Feedback divider = (98.304 * 4) / 12.288 = 32 So ● pll_fbdiv_integer (holding the seven integer bits) = 0x20 ● pll_fbdiv_frac_top (holding the top bits (MSB) of the fractional part of the divisor) = 0x00 ● pll_fbdiv_frac_bot (holding the bottom bits (LSB) of the fractional part of the divisor) = 0x00 Table 44 shows example register settings that will configure the PLL when using a 13 MHz, 15 MHz or 19.2 MHz clock. Any MCLK input frequency between 2 MHz and 54 MHz is supported. pll_indiv must be used to reduce the PLL reference frequency to the usable range of 2 MHz to 5 MHz as shown in Table 43. Table 44: Example PLL Configurations MCLK input frequency (MHz) System clock frequency (MHz) pll_mode register PLL_FRAC_TOP register PLL_FRAC_BOT register 13 11.2896 0x01 0x19 0x45 13 12.288 0x01 0x07 0xEA 15 11.2896 0x01 0x02 0xB4 15 12.288 0x01 0x06 0xDC 19.2 11.2896 0x01 0x1A 0x1C 19.2 12.288 0x01 0x0F 0x5C 11.6.6 PLL SRM Mode (DAI Slave) SRM mode enables the PLL output clock to be synchronized to the incoming WCLK signal on the DAI. The SRM PLL mode is enabled by setting pll_mode = 10. When using the DAI in slave mode with the SRM enabled, removing and re-applying the DAI interface word clock WCLK may cause the PLL lock to be lost. To re-lock the PLL it is recommended that you disable the SRM (pll_mode = 00), reset the PLL by re-writing to register PLL_INTEGER, and then re-enable the SRM (pll_mode = 10) after the DAI WCLK has been reapplied. When switching sample rates between 44.1 kHz and 48 kHz (or between the multiples of these sample rates), SRM must be disabled and then re-enabled using register bit pll_mode. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |