| Electronic Components Datasheet Search |
|
MPL3150A2ST1 Datasheet(PDF) 13 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPL3150A2ST1 Datasheet(HTML) 13 Page - NXP Semiconductors |
|
13 / 46 page ![]() NXP Semiconductors MPL3150A2S I2C precision pressure sensor 13.3 Temperature function The unit contains a high-resolution temperature sensor that provides data to the user via a 16-bit data register, as well as for internal compensation of the pressure sensor. 13.4 Autonomous data acquisition The unit can be programmed to periodically capture pressure and temperature data. Up to 32 data acquisitions can be stored in the internal FIFO. The interval between acquisitions is programmable from one second to nine hours. Data collection capabilities: (up to 32 samples over 12 days). The unit can also be programmed to make a single reading and then go to standby mode. 13.5 FIFO A 32-sample FIFO is incorporated to minimize the overhead of collecting multiple data samples. The FIFO stores both temperature and pressure data. The device can be programmed to autonomously collect data at programmed intervals and store the data in the FIFO. FIFO interrupts can be triggered by watermark full or data contention (FIFO GATE) events. 13.6 External interrupts Two independent interrupt out pins are provided. The configuration of the pins is programmable (polarity, open- drain, or push/pull.) Any one of the internal interrupt sources can be routed to either pin. 13.6.1 Reach target threshold pressure (SRC_PTH) The interrupt flag is set on reaching the value stored in the pressure target register. Additionally, a window value provides the ability to signal when the target is nearing the value in the pressure target register from either above or below. Example: • Set pressure alert to 100.0 kPa and window value to 5 kPa, interrupt can be sent passing 95 kPa, 100 kPa, and 105 kPa. Note: When the window value is set to 0, then the interrupt will only be generated when reaching or crossing the target value. 13.6.2 Reach window target pressure (SRC_PW) The interrupt flag is set when the pressure value is within the window defined by the following formula: Note: If the P_WND value is set to 0, no interrupt is generated. 13.6.3 Reach target threshold temperature (SRC_TTH) Interrupt flag is set on reaching the value stored in the temperature target register. Additionally a window value provides ability to signal when the target is nearing from either above or below the value in the temperature target register. Note: When the window value is set to 0, then the interrupt will only be generated when reaching or crossing the target value. MPL3150A2S All information provided in this document is subject to legal disclaimers. © 2023 NXP B.V. All rights reserved. Product data sheet Rev. 1.3 — 8 May 2023 13 / 46 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |