Electronic Components Datasheet Search
  New Zealand  ▼
ALLDATASHEET.CO.NZ

X  

9170A2811 Datasheet(PDF) 2 Page - KISTLER INSTRUMENT CORPORATION

Part # 9170A2811
Description  4-Component Dynamometer (RCD) Rotating – for measuring cutting forces on a rotating tool
PDF  6 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  KISTLER [KISTLER INSTRUMENT CORPORATION]
Direct Link  https://www.kistler.com/NL/en/
Logo KISTLER - KISTLER INSTRUMENT CORPORATION

9170A2811 Datasheet(HTML) 2 Page - KISTLER INSTRUMENT CORPORATION

  9170A2811 Datasheet HTML 1Page - KISTLER INSTRUMENT CORPORATION 9170A2811 Datasheet HTML 2Page - KISTLER INSTRUMENT CORPORATION 9170A2811 Datasheet HTML 3Page - KISTLER INSTRUMENT CORPORATION 9170A2811 Datasheet HTML 4Page - KISTLER INSTRUMENT CORPORATION 9170A2811 Datasheet HTML 5Page - KISTLER INSTRUMENT CORPORATION 9170A2811 Datasheet HTML 6Page - KISTLER INSTRUMENT CORPORATION  
Zoom Inzoom in Zoom Outzoom out
 2 / 6 page
background image
© 2013 ... 2019 Kistler Group,
Eulachstraße 22, 8408 Winterthur, Switzerland
Tel. +41 52 224 11 11, info@kistler.com, www.kistler.com. Kistler Group products are
protected by various intellectual property rights. For more details visit www.kistler.com
This information corresponds to the current state of knowledge. Kistler reserves
the right to make technical changes. Liability for consequential damage resulting
from the use of Kistler products is excluded.
Page 2/6
4-Component Dynamometer (RCD) – Rotating – for measuring cutting forces on a rotating tool,
Type 9170A...
Crosstalk
Fx <–> Fy
%FSO
≤±2,0
Fx,y –> Fz
%FSO
≤±3,5
Fz –> Fx,y
%FSO
≤±1,0
Fz –> Mz
mN·m/N
≤±1
Mz –> Fz
N/N·m
≤±1
Natural frequency 2)
f0, Fx,y
Hz
≈2 000
f0,Fz
Hz
≈7 600
Low-pass (anti-aliasing)
kHz
3,0
Low-pass filter Type
6 pol.,
Butterworth
Sampling rate per channel
kHz
22,2
Resolution
bit
12
Operating temperature range
°C
0 ... 60
Degree of protection (IEC 60529)
IP67
Internal cutting fluid pressure, max.
bar
70
Balancing class
G
≤2,5
Weight (rotor only) 2)
kg
1,6
2) Applies to Type 9170A131 (RCD with HSK-A63 spindle adapter,
ER clamp adapter, without tool)
Signal conditioner Type 5238Bx
Number of channels
4
Number of range per channel
3
Low-pass (adjustable)
Cut-off frequency 1
kHz
0,3
Cut-off frequency 2
kHz
1,0
Cut-off frequency 3
kHz
3,0
Low-pass filter Type
6 pol.,
Butterworth
Signal output FSO
V
±10
Connector signal output
4xBNC neg.
D-Sub neg.
15-pol.
Interface (for remote control)
RS-232C
Power supply
VAC
V
100 ... 240
Tolerance
%
±10
Mains frequency
Hz
50 ... 60
Operating temperature range
°C
0 ... 60
Degree of protection (IEC 60529)
IP30
Dimensions
WxHxD
mm
248x253x146
Weight (signal conditioner only)
kg
3,4
Advantages of a rotating Dynamometer
Employing a rotating dynamometer as a measuring tool offers
a number of advantages to the user. For example:
• The torque to be applied during the machining process is
measured directly. This permits an accurate assessment of
the condition of the tool, such as its state of wear
• The rotor of a rotating dynamometer rotates with the tool
and allows the direct quantification of the mechanical load
of the tool
• Thanks to the independence of workpiece mass, size and
shape, the cutting force and torque can be measured on
complex and cost-intensive components, e.g. structural
parts of aircraft or Blisks (Blade Integrated Disc)
Technical data
Rotor Type 9170Axxx0
Speed, max.
min–1
20 000 1)
Measuring range 1, nominal Fx, Fy
N
–5 000 ... 5 000 2)
Fz
N
–20 000 ... 20 000 2)
Mz
N·m
–150 ... 150 2)
Measuring range 2, nominal Fx, Fy
N
–2 000 ... 2 000 2)
Fz
N
–5 000 ... 5 000 2)
Mz
N·m
–50 ... 50 2)
Measuring range 3, nominal Fx, Fy
N
–500 ... 500 2)
Fz
N
–2 000 ... 2 000 2)
Mz
N·m
–10 ... 10 2)
Sensitivity range 1
Fx, Fy
mV/N
≈2
Fz
mV/N
≈0,5
Mz
mV/N·m
≈66
Sensitivity range 2
Fx, Fy
mV/N
≈5
Fz
mV/N
≈2
Mz
mV/N·m
≈200
Sensitivity range 3
Fx, Fy
mV/N
≈20
Fz
mV/N
≈5
Mz
mV/N·m
≈1 000
Linearity
%FSO
≤±1,0
Hysteresis
%FSO
≤1,0
1)
Rotors with spindle adapter DIN 69871-AD50, MAS 403 BT 50 or
ANSI B5.50-50 are limited to 12 000 min–1.
2)
Small spindle adapters limit the useable force range of the RCD. The
rotors are calibrated in accordance with limit values (see page 4).



Html Pages

1 2 3 4 5 6


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com